Struct nrf52840::power::pofcon::W[][src]

pub struct W { /* fields omitted */ }

Value to write to the register

Methods

impl W
[src]

Reset value of the register

Writes raw bits to the register

Bit 0 - Enable or disable power failure warning

Bits 1:4 - Power-fail comparator threshold setting. This setting applies both for normal voltage mode (supply connected to both VDD and VDDH) and high voltage mode (supply connected to VDDH only). Values 0-3 set threshold below 1.7 V and should not be used as brown out detection will be activated before power failure warning on such low voltages.

Bits 8:11 - Power-fail comparator threshold setting for high voltage mode (supply connected to VDDH only). This setting does not apply for normal voltage mode (supply connected to both VDD and VDDH).

Auto Trait Implementations

impl Send for W

impl Sync for W