A high-level API for Modbus Register Maps based on tokio-modbus.
§Traits
The library defines
core::InputRegisterMap
andcore::HoldingRegisterMap
traits to read from (and write to) the Modbus registers in batch, and- [
simulator::InputRegisterModel
] and [simulator::HoldingRegisterModel
] traits to simulate a Modbus device
§Derive macro
For convenience it provides derive macros to implement the traits automatically. The derive macros depends on modbus
field attribute.
See examples/ for simple usage.
The modbus
attributes can be added to struct fields to link them with modbus register mapping entries.
Then, the field modbus
must contain the following key-values pairs:
addr
- input or holding register start address,u16
integer,ty
- modbus data type, one of"i16"
,"i32"
,"i64"
,"u16"
,"u32"
,"u64"
,"f16"
,"f32"
or"raw(size)"
,ord
- word order, either"be"
for big-endian or"le"
for little-endian,x
- scale factor; multiply the stored value by it to get the actual valueunit
- measurement unit of the actual value (i.e. actual value = stored value x scale factor)
The struct modbus
attribute is optional and provides configuration for InputRegisterMap
and HoldingRegisterMap
traits when reading registers.
It can only contain these key-value pairs:
max_cnt_per_request
- maximum number of registers to read in a single Modbus request; default value is123
which is the maximumum allowed valueallow_register_gaps
- an optimization flag to allow Modbus client to read longer register blocks which possibly contain unrequested (or undefined) registers in between the required ones. Iftrue
, the client makes less requests but read more data. Otherwise, iffalse
, the client makes more requests but read only the necessary data.
The modbus_doc
attribute is to create documentation (by adding doc attribute) from modbus
field attributes information.