Expand description
§mics-6814
Platform-agnostic, no_std Rust driver for the MiCS-6814 triple gas sensor.
Converts resistance ratios (Rs/R0) from the sensor’s three independent channels into gas concentration estimates (ppm) using calibration curves from the datasheet.
§Supported Gases
| Gas | Channel | Range |
|---|---|---|
| CO | RED | 1–1000 ppm |
| NO2 | OX | 0.05–10 ppm |
| NH3 | NH3 | 1–500 ppm |
| Ethanol | RED | 10–500 ppm |
| H2 | RED | 1–1000 ppm |
| CH4 | RED | >1000 ppm |
| C3H8 | RED | >1000 ppm |
| C4H10 | RED | >1000 ppm |
§Usage
use mics_6814::{voltage_to_rs_r0, measure, ChannelReading, Gas};
// Convert ADC voltage to Rs/R0 ratio
let rs_r0 = voltage_to_rs_r0(
1.65, // ADC voltage (V)
3.3, // Supply voltage (V)
56_000.0, // Load resistor (Ω)
500_000.0, // R0 from calibration (Ω)
).unwrap();
// Build a reading and measure CO
let reading = ChannelReading { red: rs_r0, ox: 1.0, nh3: 1.0 };
let co = measure(&reading, Gas::CarbonMonoxide).unwrap();
println!("CO: {:.1} ppm", co.ppm);§Calibration
R0 must be measured in clean air after the sensor’s warm-up period (~10 minutes). Each channel has its own R0 value.
§Features
defmt-03— enabledefmt::Formatderives for embedded logging
§License
Licensed under either of Apache License, Version 2.0 or MIT license at your option.
Re-exports§
pub use calibration::rs_r0_to_ppm;pub use error::Error;pub use gas::Channel;pub use gas::Gas;
Modules§
Structs§
- Channel
Reading - Raw resistance readings from the three sensor channels.
- GasReading
- Gas concentration reading in parts per million.
Functions§
- measure
- Estimate the concentration of a specific gas from a channel reading.
- voltage_