Skip to main content

matter_kit/clusters/
on_off.rs

1//! On/Off, cluster `0x0006` (Application Cluster §1.5).
2//!
3//! The cluster every Matter demonstration starts with, and the first one in this crate where
4//! the specification defines *behaviour* rather than a table. §1.5.7 is a state machine, and
5//! most of it is not about turning a light on:
6//!
7//! ```text
8//!                        OnWithTimedOff(X, Y)
9//!         ┌──────┐  ──────────────────────────▶  ┌──────────┐
10//!         │ Off  │                               │ Timed On │  OnTime ticks down
11//!         └──────┘  ◀──────────────────────────  └──────────┘
12//!             ▲          OnTime reaches 0             │
13//!             │                                       │ Off
14//!             │         ┌─────────────┐               │
15//!             └─────────│ Delayed Off │◀──────────────┘
16//!   OffWaitTime → 0     └─────────────┘  OffWaitTime guards against
17//!                                        another OnWithTimedOff
18//! ```
19//!
20//! # What the guard is for
21//!
22//! §1.5.6.5 gives the reason `OffWaitTime` exists, and it is a real room rather than a
23//! protocol abstraction: "when leaving a room, the lights are turned off but an occupancy
24//! sensor detects the leaving person and attempts to turn the lights back on". A device that
25//! ignores the guard turns the light back on behind the person who just left, every time.
26//!
27//! # Where the device comes in
28//!
29//! This is a **pattern B1** cluster: the specification owns the state machine and the
30//! application owns the light. [`OnOffHooks`] is that seam — it is told what the cluster
31//! decided, and it makes the hardware agree. Nothing here drives a pin, and nothing in a
32//! device has to reimplement §1.5.7.
33//!
34//! The descriptor is derived from the generated tables ([`OnOff::conforming`]), so a device that
35//! claims `Lighting` serves `StartUpOnOff` and one that does not cannot accidentally
36//! advertise it.
37
38use core::cell::RefCell;
39
40use crate::clusters::generated::on_off as spec_on_off;
41use crate::dm::spec::{Conforming, Optional};
42use crate::dm::{Resolved, ResolvedCommand};
43use crate::im::{ClusterHandler, ClusterId, CommandId, InteractionContext, Status, StatusIb};
44use crate::platform::{Duration, Instant};
45use crate::tlv::{ContainerKind, Tag, TlvReader, TlvWriter, Value};
46
47use super::Cluster;
48
49pub use spec_on_off::attribute::{
50    GLOBAL_SCENE_CONTROL, OFF_WAIT_TIME, ON_OFF, ON_TIME, START_UP_ON_OFF,
51};
52pub use spec_on_off::command::{
53    OFF, OFF_WITH_EFFECT, ON, ON_WITH_RECALL_GLOBAL_SCENE, ON_WITH_TIMED_OFF, TOGGLE,
54};
55pub use spec_on_off::feature;
56pub use spec_on_off::{
57    DelayedAllOffEffectVariantEnum, DyingLightEffectVariantEnum, EffectIdentifierEnum, ID,
58    OnOffControlBitmap, PICS, REVISION, StartUpOnOffEnum,
59};
60
61/// The tick §1.5.7.6.4 counts in: "the server SHALL then update these attributes every 1/10
62/// second".
63///
64/// A device polls [`OnOff::poll`] at least this often while a timer runs; less often and the
65/// light stays on past its time, which is what a user notices.
66pub const TICK: Duration = Duration::from_millis(100);
67
68/// The value §1.5.7.6.4 exempts from counting: "If the values of the OnTime and OffWaitTime
69/// attributes are both not equal to 0xFFFF" — so `0xFFFF` means "stay like this".
70pub const INDEFINITE: u16 = 0xFFFF;
71
72/// What the application does when the cluster decides the light has changed.
73///
74/// The cluster owns §1.5.7's state machine and calls this; the device owns the hardware. A
75/// hook is not asked whether it agrees — the attribute has already changed and a client may
76/// already have been told — so the only correct implementation is one that makes the world
77/// match.
78pub trait OnOffHooks {
79    /// The light is now on, or off.
80    ///
81    /// Called for every transition, however it arose: a command, a timer expiring, a startup
82    /// value being applied. Not called when a command sets the attribute to what it already
83    /// was, because §8.6's reporting would not report that either.
84    fn set(&self, on: bool);
85
86    /// §1.5.7.4's fading effect, if the device has one.
87    ///
88    /// The default ends in the same place as an ordinary Off, which is what the specification
89    /// requires of a device with no fade: the effect is "enhanced ways of fading", and a
90    /// device without any still turns off. `variant` is advisory — "If the server does not
91    /// support the given variant, it SHALL use the default variant."
92    fn off_with_effect(&self, effect: EffectIdentifierEnum, variant: u8) {
93        let _ = (effect, variant);
94        self.set(false);
95    }
96
97    /// §1.5.7.5: recall the global scene the last `OffWithEffect` stored.
98    ///
99    /// "the Scenes Management cluster server on the same endpoint SHALL recall its global
100    /// scene, updating the OnOff attribute accordingly" — so the answer is whatever the scene
101    /// says, and a device with no Scenes Management returns `true`, which is the behaviour of
102    /// a light that simply comes back on.
103    fn recall_global_scene(&self) -> bool {
104        true
105    }
106
107    /// §1.5.7.4: store the current settings as the global scene, before turning off.
108    ///
109    /// Empty by default. A device without Scenes Management has nothing to store, and
110    /// `recall_global_scene` correspondingly has nothing to restore.
111    fn store_global_scene(&self) {}
112}
113
114/// The cluster's state (§1.5.6).
115#[derive(Debug, Clone, Copy, PartialEq, Eq)]
116struct State {
117    on: bool,
118    global_scene_control: bool,
119    on_time: u16,
120    off_wait_time: u16,
121    /// When the next 1/10-second tick is due, while either timer is running.
122    next_tick: Option<Instant>,
123}
124
125/// On/Off, with the device's hooks.
126///
127/// `H` is the application. `feature_map` decides which half of the cluster exists: without
128/// `Lighting` there is no `OnTime`, no `OffWaitTime` and therefore no timed-off state machine
129/// at all, which is exactly what a plain relay wants.
130#[derive(Debug)]
131pub struct OnOff<'a, H: OnOffHooks> {
132    hooks: &'a H,
133    feature_map: u32,
134    state: RefCell<State>,
135    start_up: Option<StartUpOnOffEnum>,
136}
137
138impl<'a, H: OnOffHooks> OnOff<'a, H> {
139    /// A cluster over `hooks`, with these features.
140    ///
141    /// `start_up` is §1.5.6.6's `StartUpOnOff`: `None` means "the previous value", which is
142    /// the fallback the specification gives and the one a device implements by restoring the
143    /// persisted `OnOff` before calling [`OnOff::start`].
144    #[must_use]
145    pub fn new(hooks: &'a H, feature_map: u32, start_up: Option<StartUpOnOffEnum>) -> Self {
146        Self {
147            hooks,
148            feature_map,
149            state: RefCell::new(State {
150                on: false,
151                // §1.5.6.3: TRUE after anything that turns the device on, FALSE after
152                // `OffWithEffect`. A device that has never been told otherwise has not stored
153                // a global scene, so there is nothing for `OnWithRecallGlobalScene` to recall
154                // and the attribute starts TRUE.
155                global_scene_control: true,
156                on_time: 0,
157                off_wait_time: 0,
158                next_tick: None,
159            }),
160            start_up,
161        }
162    }
163
164    /// Whether the cluster supports the Lighting feature's timing attributes.
165    const fn lighting(&self) -> bool {
166        self.feature_map & feature::LIGHTING != 0
167    }
168
169    /// Whether the device refuses to turn on (§1.5.4).
170    const fn off_only(&self) -> bool {
171        self.feature_map & feature::OFF_ONLY != 0
172    }
173
174    /// The descriptor for an instance with these features.
175    ///
176    /// Derived from the specification's own tables, so the element set follows the feature
177    /// map: `StartUpOnOff` and its three companions appear with `Lighting` and cannot appear
178    /// without it.
179    pub fn conforming(
180        feature_map: u32,
181        optional: &Optional<'_>,
182    ) -> crate::error::Result<Conforming<5, 6, 0, 0>> {
183        Conforming::new(&spec_on_off::CLUSTER, feature_map, optional)
184    }
185
186    /// Applies §1.5.6.6's `StartUpOnOff` — what the light does when power returns.
187    ///
188    /// `previous` is the `OnOff` value the device persisted, which is what a null
189    /// `StartUpOnOff` means: "If the value is null, the OnOff attribute is set to its previous
190    /// value."
191    ///
192    /// > This behavior does not apply to reboots associated with OTA. After an OTA restart,
193    /// > the OnOff attribute SHALL return to its value prior to the restart.
194    ///
195    /// So a device restarting for an update passes `None` for `start_up` when constructing, or
196    /// simply does not call this.
197    pub fn start(&self, previous: bool) {
198        let on = match self.start_up {
199            None => previous,
200            Some(StartUpOnOffEnum::Off) => false,
201            Some(StartUpOnOffEnum::On) => true,
202            Some(StartUpOnOffEnum::Toggle) => !previous,
203        };
204        self.set(on);
205    }
206
207    /// Whether the light is on.
208    #[must_use]
209    pub fn is_on(&self) -> bool {
210        self.state.borrow().on
211    }
212
213    /// `OnTime`, in tenths of a second.
214    #[must_use]
215    pub fn on_time(&self) -> u16 {
216        self.state.borrow().on_time
217    }
218
219    /// `OffWaitTime`, in tenths of a second.
220    #[must_use]
221    pub fn off_wait_time(&self) -> u16 {
222        self.state.borrow().off_wait_time
223    }
224
225    /// `GlobalSceneControl` (§1.5.6.3).
226    #[must_use]
227    pub fn global_scene_control(&self) -> bool {
228        self.state.borrow().global_scene_control
229    }
230
231    /// Sets the state and tells the device, if anything changed.
232    fn set(&self, on: bool) {
233        let changed = {
234            let mut state = self.state.borrow_mut();
235            let changed = state.on != on;
236            state.on = on;
237            changed
238        };
239        if changed {
240            self.hooks.set(on);
241        }
242    }
243
244    /// When [`OnOff::poll`] next has something to do.
245    ///
246    /// `None` when neither timer is running, which is the ordinary case — a light that is
247    /// simply on or simply off needs no clock at all, and an intermittently connected device
248    /// can sleep.
249    #[must_use]
250    pub fn wake_at(&self) -> Option<Instant> {
251        self.state.borrow().next_tick
252    }
253
254    /// Runs §1.5.7.6.4's tenth-of-a-second update.
255    ///
256    /// Call it whenever [`OnOff::wake_at`] comes round. It catches up on missed ticks rather
257    /// than counting calls, so a device that polls late — or was asleep — still turns the
258    /// light off at the right *time* rather than the right number of wake-ups later.
259    pub fn poll(&self, now: Instant) {
260        let mut turn_off = false;
261        {
262            let mut state = self.state.borrow_mut();
263            let Some(mut due) = state.next_tick else {
264                return;
265            };
266            // "If the values of the OnTime and OffWaitTime attributes are both not equal to
267            // 0xFFFF" — either being indefinite stops the countdown entirely.
268            if state.on_time == INDEFINITE || state.off_wait_time == INDEFINITE {
269                state.next_tick = None;
270                return;
271            }
272            let mut ticks = 0u32;
273            while now >= due && ticks < MAX_CATCH_UP {
274                ticks = ticks.saturating_add(1);
275                due = due.saturating_add(TICK);
276
277                if state.on && state.on_time > 0 {
278                    state.on_time = state.on_time.saturating_sub(1);
279                    if state.on_time == 0 {
280                        // "the server SHALL set the OffWaitTime and OnOff attributes to 0 and
281                        // FALSE, respectively."
282                        state.off_wait_time = 0;
283                        turn_off = true;
284                        state.next_tick = None;
285                        break;
286                    }
287                } else if !state.on && state.off_wait_time > 0 {
288                    state.off_wait_time = state.off_wait_time.saturating_sub(1);
289                    if state.off_wait_time == 0 {
290                        // "the server SHALL terminate the update."
291                        state.next_tick = None;
292                        break;
293                    }
294                } else {
295                    // Neither timer applies in this state; nothing left to count.
296                    state.next_tick = None;
297                    break;
298                }
299            }
300            if state.next_tick.is_some() {
301                state.next_tick = Some(due);
302            }
303        }
304        if turn_off {
305            self.set(false);
306        }
307    }
308
309    /// Arms the tick if either timer is running and both are finite.
310    fn arm(&self, now: Instant) {
311        let mut state = self.state.borrow_mut();
312        let counting = state.on_time != INDEFINITE
313            && state.off_wait_time != INDEFINITE
314            && (state.on_time > 0 || state.off_wait_time > 0);
315        state.next_tick = counting.then(|| now.saturating_add(TICK));
316    }
317}
318
319/// How many missed ticks one `poll` catches up on.
320///
321/// A minute's worth. A device that has been asleep longer than the timer it set should finish
322/// the transition rather than spin through six hundred iterations to reach the same place, and
323/// the loop's own exit conditions get there in one step once a timer hits zero.
324const MAX_CATCH_UP: u32 = 600;
325
326impl<H: OnOffHooks> OnOff<'_, H> {
327    /// §1.5.7.1's `Off`.
328    fn command_off(&self, now: Instant) {
329        self.set(false);
330        if self.lighting() {
331            // §1.5.7.1: "the server SHALL set the OnTime attribute to 0."
332            self.state.borrow_mut().on_time = 0;
333            self.arm(now);
334        }
335    }
336
337    /// §1.5.7.2's `On`.
338    fn command_on(&self, now: Instant) {
339        self.set(true);
340        if self.lighting() {
341            let mut state = self.state.borrow_mut();
342            state.global_scene_control = true;
343            if state.on_time == 0 {
344                state.off_wait_time = 0;
345            }
346            drop(state);
347            self.arm(now);
348        }
349    }
350
351    /// §1.5.7.3's `Toggle`.
352    fn command_toggle(&self, now: Instant) {
353        if self.is_on() {
354            self.command_off(now);
355        } else {
356            self.command_on(now);
357        }
358    }
359
360    /// §1.5.7.6.4's `OnWithTimedOff`.
361    fn command_on_with_timed_off(&self, control: u8, on_time: u16, off_wait: u16, now: Instant) {
362        let accept_only_when_on = control & OnOffControlBitmap::ACCEPT_ONLY_WHEN_ON.bits() != 0;
363        // "if the AcceptOnlyWhenOn sub-field of the OnOffControl field is set to 1, and the
364        // value of the OnOff attribute is equal to FALSE, the command SHALL be discarded."
365        if accept_only_when_on && !self.is_on() {
366            return;
367        }
368
369        let turn_on = {
370            let mut state = self.state.borrow_mut();
371            // "If the value of the OffWaitTime attribute is greater than zero and the value of
372            // the OnOff attribute is equal to FALSE" — the guard of §1.5.6.5, the one that
373            // stops an occupancy sensor turning the lights back on behind the person who just
374            // left the room.
375            if state.off_wait_time > 0 && !state.on {
376                state.off_wait_time = state.off_wait_time.min(off_wait);
377                false
378            } else {
379                // "set the OnTime attribute to the maximum of the OnTime attribute and the
380                // value specified in the OnTime field" — so a second command extends the
381                // period rather than shortening it.
382                state.on_time = state.on_time.max(on_time);
383                state.off_wait_time = off_wait;
384                true
385            }
386        };
387        if turn_on {
388            self.set(true);
389        }
390        self.arm(now);
391    }
392
393    /// §1.5.7.4's `OffWithEffect`.
394    fn command_off_with_effect(&self, effect: EffectIdentifierEnum, variant: u8, now: Instant) {
395        let store = {
396            let mut state = self.state.borrow_mut();
397            let store = state.global_scene_control;
398            if store {
399                state.global_scene_control = false;
400            }
401            store
402        };
403        if store {
404            // "the server SHALL store its settings in its global scene then set the
405            // GlobalSceneControl attribute to FALSE" — in that order, because the scene must
406            // capture the state the light is *in*, not the state it is about to be in.
407            self.hooks.store_global_scene();
408        }
409        self.hooks.off_with_effect(effect, variant);
410        self.set(false);
411        if self.lighting() {
412            self.state.borrow_mut().on_time = 0;
413            self.arm(now);
414        }
415    }
416
417    /// §1.5.7.5's `OnWithRecallGlobalScene`.
418    fn command_on_with_recall_global_scene(&self, now: Instant) {
419        // "if the GlobalSceneControl attribute is equal to TRUE, the server SHALL discard the
420        // command" — there is no stored scene to recall, because nothing turned the light off
421        // with an effect.
422        if self.global_scene_control() {
423            return;
424        }
425        let on = self.hooks.recall_global_scene();
426        self.set(on);
427        let mut state = self.state.borrow_mut();
428        state.global_scene_control = true;
429        if state.on_time == 0 {
430            state.off_wait_time = 0;
431        }
432        drop(state);
433        self.arm(now);
434    }
435}
436
437/// Reads `OnWithTimedOff`'s three fields (§1.5.7.6).
438fn decode_timed_off(fields: &[u8]) -> Result<(u8, u16, u16), Status> {
439    let mut reader = TlvReader::new_in(fields, ContainerKind::Structure);
440    let element = reader
441        .next_element()
442        .map_err(|_| Status::InvalidAction)?
443        .ok_or(Status::InvalidAction)?;
444    if element.value.container() != Some(ContainerKind::Structure) {
445        return Err(Status::InvalidAction);
446    }
447    let (mut control, mut on_time, mut off_wait) = (None, None, None);
448    loop {
449        let Some(field) = reader.next_element().map_err(|_| Status::InvalidAction)? else {
450            return Err(Status::InvalidAction);
451        };
452        if field.value == Value::EndOfContainer {
453            break;
454        }
455        let value = field.unsigned().map_err(|_| Status::ConstraintError)?;
456        match field.tag.context() {
457            Some(0) => {
458                // "0 to 1": the only bit defined is `AcceptOnlyWhenOn`.
459                let bits = u8::try_from(value).map_err(|_| Status::ConstraintError)?;
460                if OnOffControlBitmap::from_bits(bits).is_none() {
461                    return Err(Status::ConstraintError);
462                }
463                control = Some(bits);
464            }
465            Some(1) | Some(2) => {
466                let ticks = u16::try_from(value).map_err(|_| Status::ConstraintError)?;
467                // "max 0xFFFE" on both fields — 0xFFFF is reserved for the *attribute*'s
468                // "indefinite", and a command may not ask for it.
469                if ticks == INDEFINITE {
470                    return Err(Status::ConstraintError);
471                }
472                if field.tag.context() == Some(1) {
473                    on_time = Some(ticks);
474                } else {
475                    off_wait = Some(ticks);
476                }
477            }
478            _ => {
479                reader
480                    .skip_value(&field)
481                    .map_err(|_| Status::InvalidAction)?;
482            }
483        }
484    }
485    match (control, on_time, off_wait) {
486        (Some(control), Some(on_time), Some(off_wait)) => Ok((control, on_time, off_wait)),
487        _ => Err(Status::InvalidCommand),
488    }
489}
490
491/// Reads `OffWithEffect`'s two fields (§1.5.7.4).
492fn decode_effect(fields: &[u8]) -> Result<(EffectIdentifierEnum, u8), Status> {
493    let mut reader = TlvReader::new_in(fields, ContainerKind::Structure);
494    let element = reader
495        .next_element()
496        .map_err(|_| Status::InvalidAction)?
497        .ok_or(Status::InvalidAction)?;
498    if element.value.container() != Some(ContainerKind::Structure) {
499        return Err(Status::InvalidAction);
500    }
501    let (mut effect, mut variant) = (None, None);
502    loop {
503        let Some(field) = reader.next_element().map_err(|_| Status::InvalidAction)? else {
504            return Err(Status::InvalidAction);
505        };
506        if field.value == Value::EndOfContainer {
507            break;
508        }
509        let value = u8::try_from(field.unsigned().map_err(|_| Status::ConstraintError)?)
510            .map_err(|_| Status::ConstraintError)?;
511        match field.tag.context() {
512            // "This field SHALL contain one of the non-reserved values listed in
513            // EffectIdentifierEnum" — a reserved one is `CONSTRAINT_ERROR`, not a fade the
514            // device invents.
515            Some(0) => {
516                effect =
517                    Some(EffectIdentifierEnum::from_value(value).ok_or(Status::ConstraintError)?);
518            }
519            // The variant is *not* checked: "If the server does not support the given variant,
520            // it SHALL use the default variant", so an unknown one is the device's to shrug at.
521            Some(1) => variant = Some(value),
522            _ => {
523                reader
524                    .skip_value(&field)
525                    .map_err(|_| Status::InvalidAction)?;
526            }
527        }
528    }
529    match (effect, variant) {
530        (Some(effect), Some(variant)) => Ok((effect, variant)),
531        _ => Err(Status::InvalidCommand),
532    }
533}
534
535impl<H: OnOffHooks> ClusterHandler for OnOff<'_, H> {
536    fn read(
537        &self,
538        resolved: &Resolved<'_>,
539        _ctx: &InteractionContext<'_>,
540        w: &mut TlvWriter<'_>,
541        tag: Tag,
542    ) -> Result<(), Status> {
543        let full = |r: crate::error::Result<()>| r.map_err(|_| Status::ResourceExhausted);
544        match resolved.attribute {
545            ON_OFF => full(w.bool(tag, self.is_on())),
546            GLOBAL_SCENE_CONTROL if self.lighting() => {
547                full(w.bool(tag, self.global_scene_control()))
548            }
549            ON_TIME if self.lighting() => full(w.unsigned(tag, u64::from(self.on_time()))),
550            OFF_WAIT_TIME if self.lighting() => {
551                full(w.unsigned(tag, u64::from(self.off_wait_time())))
552            }
553            START_UP_ON_OFF if self.lighting() => match self.start_up {
554                // §1.5.6.6: null means "its previous value", which is a real answer rather
555                // than an absent one.
556                None => full(w.null(tag)),
557                Some(value) => full(w.unsigned(tag, u64::from(value.value()))),
558            },
559            _ => Err(Status::UnsupportedAttribute),
560        }
561    }
562
563    fn write(
564        &self,
565        resolved: &Resolved<'_>,
566        data: &[u8],
567        _op: crate::im::WriteOp,
568        _ctx: &InteractionContext<'_>,
569    ) -> Result<(), Status> {
570        if !self.lighting() {
571            return Err(Status::UnsupportedWrite);
572        }
573        let mut reader = TlvReader::new_in(data, ContainerKind::Structure);
574        let element = reader
575            .next_element()
576            .map_err(|_| Status::InvalidAction)?
577            .ok_or(Status::InvalidAction)?;
578        match resolved.attribute {
579            // §1.5.6.4 and §1.5.6.5: "can be written at any time, but writing a value only has
580            // effect when in the Timed On state" — so the write always lands, and the state
581            // machine decides whether it matters.
582            ON_TIME | OFF_WAIT_TIME => {
583                let value = u16::try_from(element.unsigned().map_err(|_| Status::ConstraintError)?)
584                    .map_err(|_| Status::ConstraintError)?;
585                let mut state = self.state.borrow_mut();
586                if resolved.attribute == ON_TIME {
587                    state.on_time = value;
588                } else {
589                    state.off_wait_time = value;
590                }
591                Ok(())
592            }
593            START_UP_ON_OFF => Err(Status::UnsupportedWrite),
594            _ => Err(Status::UnsupportedWrite),
595        }
596    }
597
598    fn invoke(
599        &self,
600        resolved: &ResolvedCommand<'_>,
601        fields: Option<&[u8]>,
602        ctx: &InteractionContext<'_>,
603        _w: &mut TlvWriter<'_>,
604        _tag: Tag,
605    ) -> Result<Option<CommandId>, StatusIb> {
606        let now = ctx.now;
607        match resolved.command.id {
608            OFF => {
609                self.command_off(now);
610                Ok(None)
611            }
612            // §1.5.7.2.1 and §1.5.7.3.1: "If the OffOnly feature is supported … an
613            // UNSUPPORTED_COMMAND failure status response SHALL be sent." The descriptor
614            // already leaves these out, so this is the second line of defence — and the one
615            // that matters if a device built its descriptor by hand.
616            ON if !self.off_only() => {
617                self.command_on(now);
618                Ok(None)
619            }
620            TOGGLE if !self.off_only() => {
621                self.command_toggle(now);
622                Ok(None)
623            }
624            OFF_WITH_EFFECT if self.lighting() => {
625                let (effect, variant) =
626                    decode_effect(fields.ok_or(StatusIb::from(Status::InvalidCommand))?)?;
627                self.command_off_with_effect(effect, variant, now);
628                Ok(None)
629            }
630            ON_WITH_RECALL_GLOBAL_SCENE if self.lighting() => {
631                self.command_on_with_recall_global_scene(now);
632                Ok(None)
633            }
634            ON_WITH_TIMED_OFF if self.lighting() => {
635                let (control, on_time, off_wait) =
636                    decode_timed_off(fields.ok_or(StatusIb::from(Status::InvalidCommand))?)?;
637                self.command_on_with_timed_off(control, on_time, off_wait, now);
638                Ok(None)
639            }
640            _ => Err(Status::UnsupportedCommand.into()),
641        }
642    }
643}
644
645/// So a tuple of clusters can dispatch to it by id.