Module lpc845_pac::capt::status [−][src]
Expand description
Status from triggers and time-outs including if in a poll now. Some are used for interrupts.
Structs
Field BUSY
reader - In a poll now.
Field NOTOUCH
reader - Is 1 if a no-touch has been detected (ie. completed an integration cycle and found no-touch). This is not set when in low-power mode.
Field NOTOUCH
writer - Is 1 if a no-touch has been detected (ie. completed an integration cycle and found no-touch). This is not set when in low-power mode.
Field OVERUN
reader - Is 1 if new data was collected before application read out previous ISTOUCH. No-touch (ISTOUCH==0) data will be silently overrun. Is not possible if WAIT=1.
Field OVERUN
writer - Is 1 if new data was collected before application read out previous ISTOUCH. No-touch (ISTOUCH==0) data will be silently overrun. Is not possible if WAIT=1.
Field POLLDONE
reader - Is 1 if a poll or POLLNOW is complete.
Field POLLDONE
writer - Is 1 if a poll or POLLNOW is complete.
Register STATUS
reader
Status from triggers and time-outs including if in a poll now. Some are used for interrupts.
Field TIMEOUT
reader - Is 1 if an integration cycle ended with a timeout (should not happen).
Field TIMEOUT
writer - Is 1 if an integration cycle ended with a timeout (should not happen).
Register STATUS
writer
Field XMAX
reader - Indicates the maximum number of X pins allowed 0-relative. So, 15 means there are pins 0 to 15, or 16 total X pins. INTERNAL note: this may be setup to be written by ROM boot.
Field YESTOUCH
reader - Is 1 if a touch has been detected, including a wakeup from low-power mode.
Field YESTOUCH
writer - Is 1 if a touch has been detected, including a wakeup from low-power mode.