Module lpc845_pac::usart0::cfg [−][src]
Expand description
USART Configuration register. Basic USART configuration settings that typically are not changed during operation.
Structs
Field AUTOADDR
reader - Automatic Address matching enable.
Field AUTOADDR
writer - Automatic Address matching enable.
USART Configuration register. Basic USART configuration settings that typically are not changed during operation.
Field CLKPOL
reader - Selects the clock polarity and sampling edge of received data in synchronous mode.
Field CLKPOL
writer - Selects the clock polarity and sampling edge of received data in synchronous mode.
Field CTSEN
reader - CTS Enable. Determines whether CTS is used for flow control. CTS can be from the input pin, or from the USART’s own RTS if loopback mode is enabled.
Field CTSEN
writer - CTS Enable. Determines whether CTS is used for flow control. CTS can be from the input pin, or from the USART’s own RTS if loopback mode is enabled.
Field DATALEN
reader - Selects the data size for the USART.
Field DATALEN
writer - Selects the data size for the USART.
Field ENABLE
reader - USART Enable.
Field ENABLE
writer - USART Enable.
Field LOOP
reader - Selects data loopback mode.
Field LOOP
writer - Selects data loopback mode.
Field OEPOL
reader - Output Enable Polarity.
Field OEPOL
writer - Output Enable Polarity.
Field OESEL
reader - Output Enable Select.
Field OESEL
writer - Output Enable Select.
Field OETA
reader - Output Enable Turnaround time enable for RS-485 operation.
Field OETA
writer - Output Enable Turnaround time enable for RS-485 operation.
Field PARITYSEL
reader - Selects what type of parity is used by the USART.
Field PARITYSEL
writer - Selects what type of parity is used by the USART.
Register CFG
reader
Field RXPOL
reader - Receive data polarity.
Field RXPOL
writer - Receive data polarity.
Field STOPLEN
reader - Number of stop bits appended to transmitted data. Only a single stop bit is required for received data.
Field STOPLEN
writer - Number of stop bits appended to transmitted data. Only a single stop bit is required for received data.
Field SYNCEN
reader - Selects synchronous or asynchronous operation.
Field SYNCEN
writer - Selects synchronous or asynchronous operation.
Field SYNCMST
reader - Synchronous mode Master select.
Field SYNCMST
writer - Synchronous mode Master select.
Field TXPOL
reader - Transmit data polarity.
Field TXPOL
writer - Transmit data polarity.
Register CFG
writer
Enums
Automatic Address matching enable.
Selects the clock polarity and sampling edge of received data in synchronous mode.
CTS Enable. Determines whether CTS is used for flow control. CTS can be from the input pin, or from the USART’s own RTS if loopback mode is enabled.
Selects the data size for the USART.
USART Enable.
Selects data loopback mode.
Output Enable Polarity.
Output Enable Select.
Output Enable Turnaround time enable for RS-485 operation.
Selects what type of parity is used by the USART.
Receive data polarity.
Number of stop bits appended to transmitted data. Only a single stop bit is required for received data.
Selects synchronous or asynchronous operation.
Synchronous mode Master select.
Transmit data polarity.