Enum lpc845_pac::mrt0::channel::intval::LOAD_A [−][src]
pub enum LOAD_A {
NO_FORCE_LOAD,
FORCE_LOAD,
}
Expand description
Determines how the timer interval value IVALUE -1 is loaded into the TIMERn register. This bit is write-only. Reading this bit always returns 0.
Value on reset: 0
Variants
0: No force load. The load from the INTVALn register to the TIMERn register is processed at the end of the time interval if the repeat mode is selected.
1: Force load. The INTVALn interval value IVALUE -1 is immediately loaded into the TIMERn register while TIMERn is running.