DLY_SPEC | SPI Delay register
|
FRAME_DELAY_R | Field FRAME_DELAY reader - If the EOF flag is set, controls the minimum amount of time between the current frame and the next frame (or SSEL deassertion if EOT). 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.
|
FRAME_DELAY_W | Field FRAME_DELAY writer - If the EOF flag is set, controls the minimum amount of time between the current frame and the next frame (or SSEL deassertion if EOT). 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.
|
POST_DELAY_R | Field POST_DELAY reader - Controls the amount of time between the end of a data transfer and SSEL deassertion. 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.
|
POST_DELAY_W | Field POST_DELAY writer - Controls the amount of time between the end of a data transfer and SSEL deassertion. 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.
|
PRE_DELAY_R | Field PRE_DELAY reader - Controls the amount of time between SSEL assertion and the beginning of a data transfer. There is always one SPI clock time between SSEL assertion and the first clock edge. This is not considered part of the pre-delay. 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.
|
PRE_DELAY_W | Field PRE_DELAY writer - Controls the amount of time between SSEL assertion and the beginning of a data transfer. There is always one SPI clock time between SSEL assertion and the first clock edge. This is not considered part of the pre-delay. 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.
|
R | Register DLY reader
|
TRANSFER_DELAY_R | Field TRANSFER_DELAY reader - Controls the minimum amount of time that the SSEL is deasserted between transfers. 0x0 = The minimum time that SSEL is deasserted is 1 SPI clock time. (Zero added time.) 0x1 = The minimum time that SSEL is deasserted is 2 SPI clock times. 0x2 = The minimum time that SSEL is deasserted is 3 SPI clock times. 0xF = The minimum time that SSEL is deasserted is 16 SPI clock times.
|
TRANSFER_DELAY_W | Field TRANSFER_DELAY writer - Controls the minimum amount of time that the SSEL is deasserted between transfers. 0x0 = The minimum time that SSEL is deasserted is 1 SPI clock time. (Zero added time.) 0x1 = The minimum time that SSEL is deasserted is 2 SPI clock times. 0x2 = The minimum time that SSEL is deasserted is 3 SPI clock times. 0xF = The minimum time that SSEL is deasserted is 16 SPI clock times.
|
W | Register DLY writer
|