Expand description
Probes, their records and the measurements over them, re-exported so a host that decodes or draws a scope needs one dependency, not two. Named points in the circuit and the measurements taken from them.
The board records every net transition while a trace is running and, with
analog co-simulation on, the solved voltage on each probed net at every
settle. A Channel is one probe’s slice of that record plus the numbers
a scope or a test reports: edges, period, duty, pulse widths, voltage
range. Nothing here drives or observes a part; the board owns the record
and this module turns it into something a host can print or draw.
Structs§
- Channel
- One probe with its record and the measurements over that record.
- Measurements
- The numbers a channel reports.
- Probe
- One watched point, as the board resolved it.
- Series
- What was recorded for one probe’s net, in time order.
- Trigger
- Where a logic analyzer starts its window: the first transition of
channeltolevel, withpre_ticksof history kept before it andpost_ticksrecorded after it (zero means “to the end of the record”).
Functions§
- channels
- Build the channels for
probesfrom the board’s net trace and analog samples.initialis the level every net held when recording started, emitted atstartso a channel begins with the state it actually had. - measure
- The measurements a series carries.
- summary
- One line per channel for a terminal report, e.g.
pwm: 1.000 kHz, duty 50.0%, 20 edges, pulse 500us..500us, 0.000..3.300 V. - to_csv
- A CSV with one column per channel, one row per time any channel changes, and values held between changes.
- triggered
- Cut every channel down to one trigger’s window and measure the result again. The point before the window is kept so the level at the window’s start is known, and a channel with no points inside the window still reports the level it held there.