Expand description
Live multi-inlet time-grid aligner and resampler (docs/roadmap.md, step 18).
SyncGroup combines N live numeric Inlets (enabling the opt-in
drift clock from step 17 and calibrated device delay from step 15 by
default), forwards inlet gap descriptors, and resamples all streams onto one
common monotonic time grid with bounded lookahead and bounded memory.
Structs§
- Aligned
Sample - One aligned sample on the common monotonic output grid.
- Stream
Aligner - Real-time multi-stream aligner and fractional-delay sinc resampler.
- Stream
Spec - Description of one input stream fed into
StreamAligner. - Sync
Config - Configuration for
StreamAlignerandSyncGroup. - Sync
Group - Live multi-stream aligner combining
NnumericInlets onto one common monotonic time grid.
Constants§
- DEFAULT_
GAP_ FACTOR - Default timestamp-jump multiple of
1 / nominal_sratetreated as a gap. - DEFAULT_
HALF_ WIDTH - Default half-width of the windowed-sinc kernel in source samples (
2 * 16 = 32taps). - DEFAULT_
MAX_ BUFFER_ SAMPLES - Default per-stream ring buffer capacity in samples.