Expand description
Clock measure and monitor control
Structs§
- CONTROL_
SPEC - Clock measure and monitor control
Type Aliases§
- ACCURACY_
R - Field
ACCURACYreader - measurement accuracy, 0: resolution is 1kHz 1: resolution is 1Hz - ACCURACY_
W - Field
ACCURACYwriter - measurement accuracy, 0: resolution is 1kHz 1: resolution is 1Hz - DIV_
BUSY_ R - Field
DIV_BUSYreader - divider is applying new setting - DIV_R
- Field
DIVreader - output divider - DIV_W
- Field
DIVwriter - output divider - HIGH_R
- Field
HIGHreader - clock frequency higher than upper limit - HIGH_W
- Field
HIGHwriter - clock frequency higher than upper limit - LOW_R
- Field
LOWreader - clock frequency lower than lower limit - LOW_W
- Field
LOWwriter - clock frequency lower than lower limit - MODE_R
- Field
MODEreader - work mode, 0: register value will be compared to measurement 1: upper and lower value will be recordered in register - MODE_W
- Field
MODEwriter - work mode, 0: register value will be compared to measurement 1: upper and lower value will be recordered in register - OUTEN_R
- Field
OUTENreader - enable clock output - OUTEN_W
- Field
OUTENwriter - enable clock output - R
- Register
controlreader - REFERENCE_
R - Field
REFERENCEreader - refrence clock selection, 0: 32k 1: 24M - REFERENCE_
W - Field
REFERENCEwriter - refrence clock selection, 0: 32k 1: 24M - SELECTION_
R - Field
SELECTIONreader - clock measurement selection - SELECTION_
W - Field
SELECTIONwriter - clock measurement selection - START_R
- Field
STARTreader - start measurement - START_W
- Field
STARTwriter - start measurement - VALID_R
- Field
VALIDreader - result is ready for read 0: not ready 1: result is ready - VALID_W
- Field
VALIDwriter - result is ready for read 0: not ready 1: result is ready - W
- Register
controlwriter