gridoxide’s solvers, without any file format.

Every reader and writer of a file format lives in gridoxide, on top, as do OPF, remedial actions, dynamics and the C and Python bindings. The sparse LU is gridoxide-sparse’s.

Modules§

ac_sensitivity
AC sensitivity analysis: how a converged operating point responds to a small change.
batch
Batched power flow: one topology, many scenarios, solved across all cores.
bde
Block-diagonal embedding: solve B scenarios as one sparse system.
branch_flow
Branch terminal power flows and their partial derivatives.
constrained
A switch as an exact equality constraint, rather than as a stiff branch.
continuation
Continuation power flow: how much further can this network be loaded?
dc
Real-valued DC network model and Newton-Raphson solver.
dispatch
Which machine produced what reactive power.
injection_hessian
Second derivatives of the bus power injections.
jacobian
Topology-derived Jacobian assembly: analyze the sparsity pattern once, then refill values every iteration at fixed offsets.
json
linear
Linearized power-flow methods: the two different things the literature and the reference tools both call “linear power flow”.
measurement
The measurement model state estimation is fitted against: what was observed, where, and how much it is trusted.
network
outerloop
Outer loops: the controls that sit around a Newton-Raphson solve.
qv
Q-V curves: how much reactive headroom does one bus have?
ratings
Branch operating limits — the permanent rating and its temporary overload allowances.
roots
Bracketed root finding, shared by the event locators in continuation and gridoxide’s dynamics.
scenario
What a batch varies: per-bus overrides and branch outages against a shared template, and the errors a batch reports for them.
se
State estimation: recovering the most likely grid state from noisy, redundant, partial measurements.
shortcircuit
Short-circuit calculation, IEC 60909 style.
solver
switches
Giving a retained switch a formulation.
topology
Network topology: the node/switch graph, and the reductions over it.
types

Structs§

OuterLoopOutcome
The outer loops’ side of a solve, gathered so a caller need not downcast outerloop::OuterLoop trait objects to read their reports.
PowerFlowOptions
Everything crate::run_power_flow needs to know.
PowerFlowReport
Result of a full power-flow analysis: the solved (or placeholder, for unreferenced islands) buses, plus a per-connected-component breakdown of how each one was resolved — see solver::IslandReport/ solver::IslandStatus.
RemoteControlData
The regulating machines a solve may act on.
TapData
The tap tables and regulating controls a solve may act on.

Enums§

PowerFlowInit
Where PowerFlowMethod::NewtonRaphson starts from. Ignored by the direct methods, which have no starting point.
PowerFlowMethod
Which method crate::run_power_flow uses.

Functions§

initialize_newton
Sets Newton’s starting point in buses, as run_power_flow does before its first iteration.
run_power_flow
Runs a power flow by the method named in opts.
run_power_flow_analysis
run_power_flow_analysis_from_ybus
Runs a power flow analysis given a pre-built Y-bus matrix. Intended for the 3-phase case too, where buses is a 3N-element vector and ybus is the 3N×3N phase-domain admittance matrix from build_ybus_3ph — a physical bus’s 3 phase-rows always share the same BusType, so the island partitioning PersistentSolver::solve does internally is safe for that case too (worst case, in a network with perfectly balanced zero/positive-sequence impedances, phases may partition into separate components rather than staying grouped by physical bus; each still carries its own valid reference, so this doesn’t change correctness, only granularity).
run_power_flow_with_remote
run_power_flow with the regulating machines a remote-voltage control needs. The two-argument form is the shorter path for every caller that has none, which is every importer but CGMES.