Skip to main content

frequenz_microgrid_component_graph/
config.rs

1// License: MIT
2// Copyright © 2024 Frequenz Energy-as-a-Service GmbH
3
4//! This module contains the configuration options for the `ComponentGraph`.
5
6/// Configuration options for the `ComponentGraph`.
7#[derive(Clone, Debug, Default)]
8pub struct ComponentGraphConfig {
9    /// Whether to allow validation errors on components.  When this is `true`,
10    /// the graph will be built even if there are validation errors on
11    /// components.
12    pub(crate) allow_component_validation_failures: bool,
13
14    /// Whether to allow unconnected components in the graph, that are not
15    /// reachable from the root.
16    pub(crate) allow_unconnected_components: bool,
17
18    /// Whether to allow untyped inverters in the graph.  When this is `true`,
19    /// inverters that have `InverterType::Unspecified` will be assumed to be
20    /// Battery inverters.
21    pub(crate) allow_unspecified_inverters: bool,
22
23    /// Whether to disable fallback components in generated formulas.  When this
24    /// is `true`, the formulas will not include fallback components.
25    pub(crate) disable_fallback_components: bool,
26
27    /// Meters with successors can still have loads not represented in the
28    /// component graph.  These are called phantom loads.
29    ///
30    /// When this is `true`, phantom loads are included in formulas by excluding
31    /// the measurements of successor meters from the measurements of their
32    /// predecessor meters.
33    ///
34    /// When `false`, the consumer formula instead measures whole lines — the
35    /// grid reading, or the topmost reporting meters — and subtracts the
36    /// battery, PV, CHP, EV charger, wind turbine and steam boiler chains
37    /// those readings cover.
38    pub(crate) include_phantom_loads_in_consumer_formula: bool,
39
40    /// Default policy for the per-category "component" formulas.
41    ///
42    /// When `false` (the default), the component measurement is the primary
43    /// source and the meter measurement is the fallback for the per-
44    /// category formulas (`battery_formula`, `chp_formula`, `pv_formula`,
45    /// `wind_turbine_formula`, `ev_charger_formula`, `steam_boiler_formula`).
46    /// When `true`, the meter is primary and the component is the fallback.
47    ///
48    /// Per-formula overrides live in [`formula_overrides`][Self::formula_overrides].
49    ///
50    /// Has no effect on `grid_formula`, `consumer_formula`,
51    /// `producer_formula`, or any of the coalesce formulas.
52    pub(crate) prefer_meters_in_component_formulas: bool,
53
54    /// Per-formula overrides for the meter/component preference; see
55    /// [`FormulaOverrides`].
56    pub(crate) formula_overrides: FormulaOverrides,
57}
58
59impl ComponentGraphConfig {
60    /// Effective "prefer meters" setting for [`ComponentGraph::pv_formula`][cg].
61    ///
62    /// [cg]: crate::ComponentGraph::pv_formula
63    pub(crate) fn prefer_meters_in_pv_formula(&self) -> bool {
64        self.formula_overrides
65            .prefer_meters_in_pv_formula
66            .unwrap_or(self.prefer_meters_in_component_formulas)
67    }
68
69    /// Effective "prefer meters" setting for [`ComponentGraph::battery_formula`][cg].
70    ///
71    /// [cg]: crate::ComponentGraph::battery_formula
72    pub(crate) fn prefer_meters_in_battery_formula(&self) -> bool {
73        self.formula_overrides
74            .prefer_meters_in_battery_formula
75            .unwrap_or(self.prefer_meters_in_component_formulas)
76    }
77
78    /// Effective "prefer meters" setting for [`ComponentGraph::chp_formula`][cg].
79    ///
80    /// [cg]: crate::ComponentGraph::chp_formula
81    pub(crate) fn prefer_meters_in_chp_formula(&self) -> bool {
82        self.formula_overrides
83            .prefer_meters_in_chp_formula
84            .unwrap_or(self.prefer_meters_in_component_formulas)
85    }
86
87    /// Effective "prefer meters" setting for [`ComponentGraph::ev_charger_formula`][cg].
88    ///
89    /// [cg]: crate::ComponentGraph::ev_charger_formula
90    pub(crate) fn prefer_meters_in_ev_charger_formula(&self) -> bool {
91        self.formula_overrides
92            .prefer_meters_in_ev_charger_formula
93            .unwrap_or(self.prefer_meters_in_component_formulas)
94    }
95
96    /// Effective "prefer meters" setting for [`ComponentGraph::wind_turbine_formula`][cg].
97    ///
98    /// [cg]: crate::ComponentGraph::wind_turbine_formula
99    pub(crate) fn prefer_meters_in_wind_turbine_formula(&self) -> bool {
100        self.formula_overrides
101            .prefer_meters_in_wind_turbine_formula
102            .unwrap_or(self.prefer_meters_in_component_formulas)
103    }
104
105    /// Effective "prefer meters" setting for [`ComponentGraph::steam_boiler_formula`][cg].
106    ///
107    /// [cg]: crate::ComponentGraph::steam_boiler_formula
108    pub(crate) fn prefer_meters_in_steam_boiler_formula(&self) -> bool {
109        self.formula_overrides
110            .prefer_meters_in_steam_boiler_formula
111            .unwrap_or(self.prefer_meters_in_component_formulas)
112    }
113
114    /// Returns a [`ComponentGraphConfigBuilder`] initialised with all
115    /// options set to their default values.
116    pub fn builder() -> ComponentGraphConfigBuilder {
117        ComponentGraphConfigBuilder::new()
118    }
119}
120
121/// Builder for [`ComponentGraphConfig`].
122///
123/// Each method sets the corresponding option and returns `self`, so calls
124/// can be chained. Call [`build`][Self::build] to obtain the final
125/// `ComponentGraphConfig`.
126#[derive(Clone, Debug)]
127pub struct ComponentGraphConfigBuilder {
128    inner: ComponentGraphConfig,
129}
130
131impl ComponentGraphConfigBuilder {
132    /// Creates a new builder with all options set to their default values.
133    #[allow(clippy::new_without_default)]
134    pub fn new() -> Self {
135        Self {
136            inner: ComponentGraphConfig::default(),
137        }
138    }
139
140    /// When `true`, the graph is built even if per-component validation
141    /// rules fail; failures are reported as `tracing::warn!` instead of
142    /// returning an error.
143    pub fn allow_component_validation_failures(mut self, value: bool) -> Self {
144        self.inner.allow_component_validation_failures = value;
145        self
146    }
147
148    /// When `true`, components that are not reachable from the root are
149    /// permitted; otherwise the graph fails to build.
150    /// [Pass-through components](crate#pass-through-components) never have to
151    /// be reachable.
152    pub fn allow_unconnected_components(mut self, value: bool) -> Self {
153        self.inner.allow_unconnected_components = value;
154        self
155    }
156
157    /// When `true`, inverters with `InverterType::Unspecified` are
158    /// treated as battery inverters instead of being rejected.
159    pub fn allow_unspecified_inverters(mut self, value: bool) -> Self {
160        self.inner.allow_unspecified_inverters = value;
161        self
162    }
163
164    /// When `true`, generated formulas omit fallback components.
165    pub fn disable_fallback_components(mut self, value: bool) -> Self {
166        self.inner.disable_fallback_components = value;
167        self
168    }
169
170    /// Controls how the consumer formula handles meters with successors,
171    /// which can carry loads not represented in the graph (phantom loads).
172    ///
173    /// When `true`, phantom loads are included by subtracting successor
174    /// meter measurements from their predecessor meter's measurements.
175    /// When `false`, the consumer formula instead measures whole lines — the
176    /// grid reading, or the topmost reporting meters — and subtracts the
177    /// battery, PV, CHP, EV charger, wind turbine and steam boiler chains
178    /// those readings cover.
179    pub fn include_phantom_loads_in_consumer_formula(mut self, value: bool) -> Self {
180        self.inner.include_phantom_loads_in_consumer_formula = value;
181        self
182    }
183
184    /// Sets the global meter-vs-component source preference for the
185    /// per-category formulas. See the field-level docs on
186    /// [`ComponentGraphConfig`] for the exact list of affected formulas.
187    pub fn prefer_meters_in_component_formulas(mut self, value: bool) -> Self {
188        self.inner.prefer_meters_in_component_formulas = value;
189        self
190    }
191
192    /// Sets the per-formula overrides for the meter/component preference.
193    /// Each override, when `Some(_)`, takes precedence over
194    /// [`prefer_meters_in_component_formulas`][Self::prefer_meters_in_component_formulas]
195    /// for that formula.
196    pub fn formula_overrides(mut self, overrides: FormulaOverrides) -> Self {
197        self.inner.formula_overrides = overrides;
198        self
199    }
200
201    /// Consumes the builder and returns the resulting [`ComponentGraphConfig`].
202    pub fn build(self) -> ComponentGraphConfig {
203        self.inner
204    }
205}
206
207/// Per-formula overrides for the meter/component preference in the
208/// per-category formulas.
209///
210/// Each field is `None` by default, meaning the corresponding formula
211/// follows the global `prefer_meters_in_component_formulas` setting on
212/// [`ComponentGraphConfig`]. Setting an entry to `Some(true)` forces
213/// the meter as primary for that formula; `Some(false)` forces the
214/// component.
215///
216/// Construct via [`FormulaOverrides::builder`] or
217/// [`FormulaOverrides::default`].
218#[derive(Clone, Default, Debug)]
219pub struct FormulaOverrides {
220    pub(crate) prefer_meters_in_pv_formula: Option<bool>,
221    pub(crate) prefer_meters_in_battery_formula: Option<bool>,
222    pub(crate) prefer_meters_in_chp_formula: Option<bool>,
223    pub(crate) prefer_meters_in_ev_charger_formula: Option<bool>,
224    pub(crate) prefer_meters_in_wind_turbine_formula: Option<bool>,
225    pub(crate) prefer_meters_in_steam_boiler_formula: Option<bool>,
226}
227
228impl FormulaOverrides {
229    /// Returns a [`FormulaOverridesBuilder`] with no overrides set.
230    pub fn builder() -> FormulaOverridesBuilder {
231        FormulaOverridesBuilder::new()
232    }
233}
234
235/// Builder for [`FormulaOverrides`].
236#[derive(Clone, Debug)]
237pub struct FormulaOverridesBuilder {
238    inner: FormulaOverrides,
239}
240
241impl FormulaOverridesBuilder {
242    /// Creates a new builder with no overrides set.
243    #[allow(clippy::new_without_default)]
244    pub fn new() -> Self {
245        Self {
246            inner: FormulaOverrides::default(),
247        }
248    }
249
250    /// Override the meter/component preference for
251    /// [`ComponentGraph::pv_formula`][cg].
252    ///
253    /// [cg]: crate::ComponentGraph::pv_formula
254    pub fn prefer_meters_in_pv_formula(mut self, value: bool) -> Self {
255        self.inner.prefer_meters_in_pv_formula = Some(value);
256        self
257    }
258
259    /// Override the meter/component preference for
260    /// [`ComponentGraph::battery_formula`][cg].
261    ///
262    /// [cg]: crate::ComponentGraph::battery_formula
263    pub fn prefer_meters_in_battery_formula(mut self, value: bool) -> Self {
264        self.inner.prefer_meters_in_battery_formula = Some(value);
265        self
266    }
267
268    /// Override the meter/component preference for
269    /// [`ComponentGraph::chp_formula`][cg].
270    ///
271    /// [cg]: crate::ComponentGraph::chp_formula
272    pub fn prefer_meters_in_chp_formula(mut self, value: bool) -> Self {
273        self.inner.prefer_meters_in_chp_formula = Some(value);
274        self
275    }
276
277    /// Override the meter/component preference for
278    /// [`ComponentGraph::ev_charger_formula`][cg].
279    ///
280    /// [cg]: crate::ComponentGraph::ev_charger_formula
281    pub fn prefer_meters_in_ev_charger_formula(mut self, value: bool) -> Self {
282        self.inner.prefer_meters_in_ev_charger_formula = Some(value);
283        self
284    }
285
286    /// Override the meter/component preference for
287    /// [`ComponentGraph::wind_turbine_formula`][cg].
288    ///
289    /// [cg]: crate::ComponentGraph::wind_turbine_formula
290    pub fn prefer_meters_in_wind_turbine_formula(mut self, value: bool) -> Self {
291        self.inner.prefer_meters_in_wind_turbine_formula = Some(value);
292        self
293    }
294
295    /// Override the meter/component preference for
296    /// [`ComponentGraph::steam_boiler_formula`][cg].
297    ///
298    /// [cg]: crate::ComponentGraph::steam_boiler_formula
299    pub fn prefer_meters_in_steam_boiler_formula(mut self, value: bool) -> Self {
300        self.inner.prefer_meters_in_steam_boiler_formula = Some(value);
301        self
302    }
303
304    /// Consumes the builder and returns the resulting [`FormulaOverrides`].
305    pub fn build(self) -> FormulaOverrides {
306        self.inner
307    }
308}