Expand description
Estimating sample acquisition times from packet arrival times.
A packet carrying samples n .. n+k cannot arrive before its last sample was acquired, and
Bluetooth only adds delay. So, for a stream sampled at a steady rate, the true clock
t(n) = a + b·n is the lower envelope of (index of last sample, arrival time): arrivals lie
on or above it. fit_lower_envelope finds that line by iteratively refitting least squares to
the earliest-arriving packets. 1/b is the measured sample rate; residuals are the delivery
latency beyond the minimum (jitter).
Structs§
- Clock
Fit - A fitted clock for one uninterrupted segment of one stream.
- Placed
- Where a packet’s samples sit within a stream: which uninterrupted segment, and the index of its first sample in that segment.
- Segmenter
- Assigns packets of one stream to segments and sample indices, one packet at a time.
Functions§
- fit_
lower_ envelope - Fits the lower envelope of
(last_sample_index, arrival_unix_s)pairs. With fewer than 20 packets, the nominal period is used and only the offset is fitted. - fit_
nominal - Fits only the offset, taking the sample rate as
nominal_rate_hz. For when there is too little data to trust a fitted rate.