Module esp32s3::sdhost::idinten

source ·
Expand description

IDMAC interrupt enable register

Structs§

Type Aliases§

  • Field AI reader - Abnormal Interrupt Summary Enable. When set, an abnormal interrupt is enabled. This bit enables the following bits: IDINTEN[2]: Fatal Bus Error Interrupt; IDINTEN[4]: DU Interrupt.
  • Field AI writer - Abnormal Interrupt Summary Enable. When set, an abnormal interrupt is enabled. This bit enables the following bits: IDINTEN[2]: Fatal Bus Error Interrupt; IDINTEN[4]: DU Interrupt.
  • Field CES reader - Card Error summary Interrupt Enable. When set, it enables the Card Interrupt summary.
  • Field CES writer - Card Error summary Interrupt Enable. When set, it enables the Card Interrupt summary.
  • Field DU reader - Descriptor Unavailable Interrupt. When set along with Abnormal Interrupt Summary Enable, the DU interrupt is enabled.
  • Field DU writer - Descriptor Unavailable Interrupt. When set along with Abnormal Interrupt Summary Enable, the DU interrupt is enabled.
  • Field FBE reader - Fatal Bus Error Enable. When set with Abnormal Interrupt Summary Enable, the Fatal Bus Error Interrupt is enabled. When reset, Fatal Bus Error Enable Interrupt is disabled.
  • Field FBE writer - Fatal Bus Error Enable. When set with Abnormal Interrupt Summary Enable, the Fatal Bus Error Interrupt is enabled. When reset, Fatal Bus Error Enable Interrupt is disabled.
  • Field NI reader - Normal Interrupt Summary Enable. When set, a normal interrupt is enabled. When reset, a normal interrupt is disabled. This bit enables the following bits: IDINTEN[0]: Transmit Interrupt; IDINTEN[1]: Receive Interrupt.
  • Field NI writer - Normal Interrupt Summary Enable. When set, a normal interrupt is enabled. When reset, a normal interrupt is disabled. This bit enables the following bits: IDINTEN[0]: Transmit Interrupt; IDINTEN[1]: Receive Interrupt.
  • Register IDINTEN reader
  • Field RI reader - Receive Interrupt Enable. When set with Normal Interrupt Summary Enable, Receive Interrupt is enabled. When reset, Receive Interrupt is disabled.
  • Field RI writer - Receive Interrupt Enable. When set with Normal Interrupt Summary Enable, Receive Interrupt is enabled. When reset, Receive Interrupt is disabled.
  • Field TI reader - Transmit Interrupt Enable. When set with Normal Interrupt Summary Enable, Transmit Interrupt is enabled. When reset, Transmit Interrupt is disabled.
  • Field TI writer - Transmit Interrupt Enable. When set with Normal Interrupt Summary Enable, Transmit Interrupt is enabled. When reset, Transmit Interrupt is disabled.
  • Register IDINTEN writer