Expand description

LCD configuration register

Structs

LCD configuration register
Register LCD_USER reader
Register LCD_USER writer

Type Definitions

Field LCD_2BYTE_EN reader - 1: The bit number of output LCD data is 9~16. 0: The bit number of output LCD data is 0~8.
Field LCD_2BYTE_EN writer - 1: The bit number of output LCD data is 9~16. 0: The bit number of output LCD data is 0~8.
Field LCD_8BITS_ORDER reader - 1: invert every two data byte, valid in 1 byte mode. 0: Not change.
Field LCD_8BITS_ORDER writer - 1: invert every two data byte, valid in 1 byte mode. 0: Not change.
Field LCD_ALWAYS_OUT_EN reader - LCD always output when LCD is in LCD_DOUT state, unless reg_lcd_start is cleared or reg_lcd_reset is set.
Field LCD_ALWAYS_OUT_EN writer - LCD always output when LCD is in LCD_DOUT state, unless reg_lcd_start is cleared or reg_lcd_reset is set.
Field LCD_BIT_ORDER reader - 1: Change data bit order, change LCD_DATA_out[7:0] to LCD_DATA_out[0:7] in one byte mode, and bits[15:0] to bits[0:15] in two byte mode. 0: Not change.
Field LCD_BIT_ORDER writer - 1: Change data bit order, change LCD_DATA_out[7:0] to LCD_DATA_out[0:7] in one byte mode, and bits[15:0] to bits[0:15] in two byte mode. 0: Not change.
Field LCD_BYTE_ORDER reader - 1: invert data byte order, only valid in 2 byte mode. 0: Not change.
Field LCD_BYTE_ORDER writer - 1: invert data byte order, only valid in 2 byte mode. 0: Not change.
Field LCD_CMD_2_CYCLE_EN reader - The cycle length of command phase. 1: 2 cycles. 0: 1 cycle.
Field LCD_CMD_2_CYCLE_EN writer - The cycle length of command phase. 1: 2 cycles. 0: 1 cycle.
Field LCD_CMD reader - 1: Be able to send command in LCD sequence when LCD starts. 0: Disable.
Field LCD_CMD writer - 1: Be able to send command in LCD sequence when LCD starts. 0: Disable.
Field LCD_DOUT_CYCLELEN reader - The output data cycles minus 1 of LCD module.
Field LCD_DOUT_CYCLELEN writer - The output data cycles minus 1 of LCD module.
Field LCD_DOUT reader - 1: Be able to send data out in LCD sequence when LCD starts. 0: Disable.
Field LCD_DOUT writer - 1: Be able to send data out in LCD sequence when LCD starts. 0: Disable.
Field LCD_DUMMY_CYCLELEN reader - The dummy cycle length minus 1.
Field LCD_DUMMY_CYCLELEN writer - The dummy cycle length minus 1.
Field LCD_DUMMY reader - 1: Enable DUMMY phase in LCD sequence when LCD starts. 0: Disable.
Field LCD_DUMMY writer - 1: Enable DUMMY phase in LCD sequence when LCD starts. 0: Disable.
Field LCD_RESET writer - The value of command.
Field LCD_START reader - LCD start sending data enable signal, valid in high level.
Field LCD_START writer - LCD start sending data enable signal, valid in high level.
Field LCD_UPDATE reader - 1: Update LCD registers, will be cleared by hardware. 0 : Not care.
Field LCD_UPDATE writer - 1: Update LCD registers, will be cleared by hardware. 0 : Not care.