Module esp32s3_hal::pac::lcd_cam::lcd_user
Expand description
LCD configuration register
Structs
Type Definitions
Field
LCD_2BYTE_EN
reader - 1: The bit number of output LCD data is 9~16. 0: The bit number of output LCD data is 0~8.Field
LCD_2BYTE_EN
writer - 1: The bit number of output LCD data is 9~16. 0: The bit number of output LCD data is 0~8.Field
LCD_8BITS_ORDER
reader - 1: invert every two data byte, valid in 1 byte mode. 0: Not change.Field
LCD_8BITS_ORDER
writer - 1: invert every two data byte, valid in 1 byte mode. 0: Not change.Field
LCD_ALWAYS_OUT_EN
reader - LCD always output when LCD is in LCD_DOUT state, unless reg_lcd_start is cleared or reg_lcd_reset is set.Field
LCD_ALWAYS_OUT_EN
writer - LCD always output when LCD is in LCD_DOUT state, unless reg_lcd_start is cleared or reg_lcd_reset is set.Field
LCD_BIT_ORDER
reader - 1: Change data bit order, change LCD_DATA_out[7:0] to LCD_DATA_out[0:7] in one byte mode, and bits[15:0] to bits[0:15] in two byte mode. 0: Not change.Field
LCD_BIT_ORDER
writer - 1: Change data bit order, change LCD_DATA_out[7:0] to LCD_DATA_out[0:7] in one byte mode, and bits[15:0] to bits[0:15] in two byte mode. 0: Not change.Field
LCD_BYTE_ORDER
reader - 1: invert data byte order, only valid in 2 byte mode. 0: Not change.Field
LCD_BYTE_ORDER
writer - 1: invert data byte order, only valid in 2 byte mode. 0: Not change.Field
LCD_CMD_2_CYCLE_EN
reader - The cycle length of command phase. 1: 2 cycles. 0: 1 cycle.Field
LCD_CMD_2_CYCLE_EN
writer - The cycle length of command phase. 1: 2 cycles. 0: 1 cycle.Field
LCD_CMD
reader - 1: Be able to send command in LCD sequence when LCD starts. 0: Disable.Field
LCD_CMD
writer - 1: Be able to send command in LCD sequence when LCD starts. 0: Disable.Field
LCD_DOUT_CYCLELEN
reader - The output data cycles minus 1 of LCD module.Field
LCD_DOUT_CYCLELEN
writer - The output data cycles minus 1 of LCD module.Field
LCD_DOUT
reader - 1: Be able to send data out in LCD sequence when LCD starts. 0: Disable.Field
LCD_DOUT
writer - 1: Be able to send data out in LCD sequence when LCD starts. 0: Disable.Field
LCD_DUMMY_CYCLELEN
reader - The dummy cycle length minus 1.Field
LCD_DUMMY_CYCLELEN
writer - The dummy cycle length minus 1.Field
LCD_DUMMY
reader - 1: Enable DUMMY phase in LCD sequence when LCD starts. 0: Disable.Field
LCD_DUMMY
writer - 1: Enable DUMMY phase in LCD sequence when LCD starts. 0: Disable.Field
LCD_RESET
writer - The value of command.Field
LCD_START
reader - LCD start sending data enable signal, valid in high level.Field
LCD_START
writer - LCD start sending data enable signal, valid in high level.Field
LCD_UPDATE
reader - 1: Update LCD registers, will be cleared by hardware. 0 : Not care.Field
LCD_UPDATE
writer - 1: Update LCD registers, will be cleared by hardware. 0 : Not care.