Module esp32s2::spi0::dma_int_clr

source ·
Expand description

SPI DMA interrupt clear register

Structs

Type Aliases

  • Field INFIFO_FULL_ERR_INT_CLR reader - 1: Clear SPI_INFIFO_FULL_ERR_INT_RAW. 0: not valid. Can be changed by CONF_buf.
  • Field INFIFO_FULL_ERR_INT_CLR writer - 1: Clear SPI_INFIFO_FULL_ERR_INT_RAW. 0: not valid. Can be changed by CONF_buf.
  • Field INLINK_DSCR_EMPTY_INT_CLR reader - The clear bit for lack of enough inlink descriptors. Can be configured in CONF state.
  • Field INLINK_DSCR_EMPTY_INT_CLR writer - The clear bit for lack of enough inlink descriptors. Can be configured in CONF state.
  • Field INLINK_DSCR_ERROR_INT_CLR reader - The clear bit for inlink descriptor error. Can be configured in CONF state.
  • Field INLINK_DSCR_ERROR_INT_CLR writer - The clear bit for inlink descriptor error. Can be configured in CONF state.
  • Field IN_DONE_INT_CLR reader - The clear bit for completing usage of a inlink descriptor. Can be configured in CONF state.
  • Field IN_DONE_INT_CLR writer - The clear bit for completing usage of a inlink descriptor. Can be configured in CONF state.
  • Field IN_ERR_EOF_INT_CLR reader - The clear bit for receiving error. Can be configured in CONF state.
  • Field IN_ERR_EOF_INT_CLR writer - The clear bit for receiving error. Can be configured in CONF state.
  • Field IN_SUC_EOF_INT_CLR reader - The clear bit for completing receiving all the packets from host. Can be configured in CONF state.
  • Field IN_SUC_EOF_INT_CLR writer - The clear bit for completing receiving all the packets from host. Can be configured in CONF state.
  • Field OUTFIFO_EMPTY_ERR_INT_CLR reader - 1: Clear SPI_OUTFIFO_EMPTY_ERR_INT_RAW signal. 0: not valid. Can be changed by CONF_buf.
  • Field OUTFIFO_EMPTY_ERR_INT_CLR writer - 1: Clear SPI_OUTFIFO_EMPTY_ERR_INT_RAW signal. 0: not valid. Can be changed by CONF_buf.
  • Field OUTLINK_DSCR_ERROR_INT_CLR reader - The clear bit for outlink descriptor error. Can be configured in CONF state.
  • Field OUTLINK_DSCR_ERROR_INT_CLR writer - The clear bit for outlink descriptor error. Can be configured in CONF state.
  • Field OUT_DONE_INT_CLR reader - The clear bit for completing usage of a outlink descriptor. Can be configured in CONF state.
  • Field OUT_DONE_INT_CLR writer - The clear bit for completing usage of a outlink descriptor. Can be configured in CONF state.
  • Field OUT_EOF_INT_CLR reader - The clear bit for sending a packet to host done. Can be configured in CONF state.
  • Field OUT_EOF_INT_CLR writer - The clear bit for sending a packet to host done. Can be configured in CONF state.
  • Field OUT_TOTAL_EOF_INT_CLR reader - The clear bit for sending all the packets to host done. Can be configured in CONF state.
  • Field OUT_TOTAL_EOF_INT_CLR writer - The clear bit for sending all the packets to host done. Can be configured in CONF state.
  • Register DMA_INT_CLR reader
  • Field SLV_CMD6_INT_CLR reader - The clear bit for SPI slave CMD6 interrupt.
  • Field SLV_CMD6_INT_CLR writer - The clear bit for SPI slave CMD6 interrupt.
  • Field SLV_CMD7_INT_CLR reader - The clear bit for SPI slave CMD7 interrupt.
  • Field SLV_CMD7_INT_CLR writer - The clear bit for SPI slave CMD7 interrupt.
  • Field SLV_CMD8_INT_CLR reader - The clear bit for SPI slave CMD8 interrupt.
  • Field SLV_CMD8_INT_CLR writer - The clear bit for SPI slave CMD8 interrupt.
  • Field SLV_CMD9_INT_CLR reader - The clear bit for SPI slave CMD9 interrupt.
  • Field SLV_CMD9_INT_CLR writer - The clear bit for SPI slave CMD9 interrupt.
  • Field SLV_CMDA_INT_CLR reader - The clear bit for SPI slave CMDA interrupt.
  • Field SLV_CMDA_INT_CLR writer - The clear bit for SPI slave CMDA interrupt.
  • Register DMA_INT_CLR writer