SPI0 module clock select register
Structs§
- CORE_
CLK_ SEL_ SPEC - SPI0 module clock select register
Type Aliases§
- R
- Register
CORE_CLK_SEL
reader - SPI01_
CLK_ SEL_ R - Field
SPI01_CLK_SEL
reader - When the digital system clock selects PLL clock and the frequency of PLL clock is 480MHz, the value of reg_spi01_clk_sel: 0: SPI0/1 module clock (clk) is 80MHz. 1: SPI0/1 module clock (clk) is 120MHz. 2: SPI0/1 module clock (clk) 160MHz. 3: Not used. When the digital system clock selects PLL clock and the frequency of PLL clock is 320MHz, the value of reg_spi01_clk_sel: 0: SPI0/1 module clock (clk) is 80MHz. 1: SPI0/1 module clock (clk) is 80MHz. 2: SPI0/1 module clock (clk) 160MHz. 3: Not used. - SPI01_
CLK_ SEL_ W - Field
SPI01_CLK_SEL
writer - When the digital system clock selects PLL clock and the frequency of PLL clock is 480MHz, the value of reg_spi01_clk_sel: 0: SPI0/1 module clock (clk) is 80MHz. 1: SPI0/1 module clock (clk) is 120MHz. 2: SPI0/1 module clock (clk) 160MHz. 3: Not used. When the digital system clock selects PLL clock and the frequency of PLL clock is 320MHz, the value of reg_spi01_clk_sel: 0: SPI0/1 module clock (clk) is 80MHz. 1: SPI0/1 module clock (clk) is 80MHz. 2: SPI0/1 module clock (clk) 160MHz. 3: Not used. - W
- Register
CORE_CLK_SEL
writer