Driver for the Goertek SPL06-001 and the register-compatible SPL06-007 digital barometric pressure sensor.
The SPL06-001 / SPL06-007 is a calibrated digital barometer with 24-bit
pressure and temperature conversion results. This crate provides both an
asynchronous driver (SPL06) and a blocking one (blocking::SPL06)
with identical APIs, built on embedded-hal v1.
§Compensation
The datasheet defines the compensation as a real-number polynomial (SPL06-001 V1.0 sections 5.7.1/5.7.2, SPL06-007 V1.0 sections 5.6.1/5.6.2):
Traw_sc = Traw / kT
Praw_sc = Praw / kP
Tcomp(degC) = c0 * 0.5 + c1 * Traw_sc
Pcomp(Pa) = c00 + Praw_sc * (c10 + Praw_sc * (c20 + Praw_sc * c30))
+ Traw_sc * c01
+ Traw_sc * Praw_sc * (c11 + Praw_sc * c21)kP and kT are not constants. Each depends on the configured
oversampling rate (Table 7 of the SPL06-001 datasheet), so the raw 24-bit
values must be divided by the factor that belongs to the oversampling the
driver is actually using. Using the wrong factor silently produces a
plausible-looking but wrong reading.
The driver evaluates the polynomial in integer Q24 fixed-point arithmetic,
so it does no floating point itself; the f32 accessors on Measurements
are the only conversion and stay out of the generated code for a target
without an FPU unless they are actually called.
§Init and reset
SPL06::init reads the product/revision ID register (0x0D, expected
value PRODUCT_ID = 0x10) and the 18-byte calibration block at 0x10,
then programs the default oversampling. Like edrv-bme280 and
edrv-bme680, init deliberately does not soft reset;
SPL06::reset is a separate, explicit step.
§Licence
This crate is distributed under MIT OR Apache-2.0.
Modules§
Structs§
- Calibration
Data - Calibration coefficients, named after the datasheet’s
COEFregisters. - Config
- Oversampling configuration, with the register writes it implies.
- Measurements
- One compensated measurement.
- SPL06
- Async SPL06-001 / SPL06-007 driver.
Enums§
- Error
- Errors returned by the SPL06 driver.
- Oversampling
- Oversampling (precision) setting for one measurement channel.
Constants§
- ADDRESS
- I2C address with
SDOhigh - the sensor’s default address. - ADDRESS_
ALT - I2C address with
SDOpulled down to GND. - PRODUCT_
ID - Value expected in the product/revision ID register (
regs::ID). - SOFT_
RESET_ COMMAND - Value written to
regs::RESETto trigger a soft reset.