Skip to main content

arrival_floor_ms

Function arrival_floor_ms 

Source
pub fn arrival_floor_ms(remote_declared: u32) -> u64
Expand description

The receiver’s minimum inter-arrival floor in milliseconds for data messages, given the sender’s handshake-declared interval (SPEC §6.4): max(declared, PEX_MIN_INTERVAL) − PEX_ARRIVAL_GRACE, in ms. A data message arriving less than this after the previous one is a rate violation.