Alarm lifecycle: latch on START, clear on STOP, acknowledge, and history.

§The trap this crate exists to close

Camera events come in pairs. Code=VideoMotion;action=Start is followed, eventually, by action=Stop. Code that treats every event as “something happened” latches every alarm on forever, and an operator faced with a panel that is permanently red learns to ignore it — which is worse than having no panel.

So AlarmRegistry models the pair explicitly:

  START ────────────▶ Active ────── STOP ──────▶ Cleared
                         │
                         └── auto_clear elapsed ──▶ Cleared (timed out)

A STOP is not guaranteed. The camera reboots mid-incident, the link drops, a firmware bug swallows the edge. So every active alarm also carries an auto-clear deadline, and an alarm that outlives it is cleared with ClearReason::Timeout — recorded distinctly, because “the condition ended” and “we stopped believing the condition” are different facts and an operator needs to tell them apart.

§No background task

Expiry is evaluated lazily, when events arrive or the registry is read, against a clock the caller supplies. That is deliberate: the workspace budget allows no feature more than one task per camera, and the event link already spends it. A timer wheel here would spend a second.

§Safety

An alarm raised by camera analytics is an operator aid and is not safety-rated. The absence of an alarm means nothing. See SAFETY.md at the workspace root.

Structs§

Alarm
A latched condition on one camera.
AlarmConfig
Tuning for AlarmRegistry.
AlarmRegistry
Tracks which conditions are currently latched, and what happened before.

Enums§

AlarmChange
What changed as a result of feeding in an event.
ClearReason
Why an alarm stopped being active.

Constants§

DEFAULT_AUTO_CLEAR
How long an active alarm survives without a matching STOP.