Struct nrf52811_pac::saadc::RegisterBlock[][src]

#[repr(C)]
pub struct RegisterBlock {
Show 21 fields pub tasks_start: Reg<TASKS_START_SPEC>, pub tasks_sample: Reg<TASKS_SAMPLE_SPEC>, pub tasks_stop: Reg<TASKS_STOP_SPEC>, pub tasks_calibrateoffset: Reg<TASKS_CALIBRATEOFFSET_SPEC>, pub events_started: Reg<EVENTS_STARTED_SPEC>, pub events_end: Reg<EVENTS_END_SPEC>, pub events_done: Reg<EVENTS_DONE_SPEC>, pub events_resultdone: Reg<EVENTS_RESULTDONE_SPEC>, pub events_calibratedone: Reg<EVENTS_CALIBRATEDONE_SPEC>, pub events_stopped: Reg<EVENTS_STOPPED_SPEC>, pub events_ch: [EVENTS_CH; 8], pub inten: Reg<INTEN_SPEC>, pub intenset: Reg<INTENSET_SPEC>, pub intenclr: Reg<INTENCLR_SPEC>, pub status: Reg<STATUS_SPEC>, pub enable: Reg<ENABLE_SPEC>, pub ch: [CH; 8], pub resolution: Reg<RESOLUTION_SPEC>, pub oversample: Reg<OVERSAMPLE_SPEC>, pub samplerate: Reg<SAMPLERATE_SPEC>, pub result: RESULT, // some fields omitted
}
Expand description

Register block

Fields

tasks_start: Reg<TASKS_START_SPEC>

0x00 - Start the ADC and prepare the result buffer in RAM

tasks_sample: Reg<TASKS_SAMPLE_SPEC>

0x04 - Take one ADC sample, if scan is enabled all channels are sampled

tasks_stop: Reg<TASKS_STOP_SPEC>

0x08 - Stop the ADC and terminate any on-going conversion

tasks_calibrateoffset: Reg<TASKS_CALIBRATEOFFSET_SPEC>

0x0c - Starts offset auto-calibration

events_started: Reg<EVENTS_STARTED_SPEC>

0x100 - The ADC has started

events_end: Reg<EVENTS_END_SPEC>

0x104 - The ADC has filled up the Result buffer

events_done: Reg<EVENTS_DONE_SPEC>

0x108 - A conversion task has been completed. Depending on the mode, multiple conversions might be needed for a result to be transferred to RAM.

events_resultdone: Reg<EVENTS_RESULTDONE_SPEC>

0x10c - A result is ready to get transferred to RAM.

events_calibratedone: Reg<EVENTS_CALIBRATEDONE_SPEC>

0x110 - Calibration is complete

events_stopped: Reg<EVENTS_STOPPED_SPEC>

0x114 - The ADC has stopped

events_ch: [EVENTS_CH; 8]

0x118..0x158 - Peripheral events.

inten: Reg<INTEN_SPEC>

0x300 - Enable or disable interrupt

intenset: Reg<INTENSET_SPEC>

0x304 - Enable interrupt

intenclr: Reg<INTENCLR_SPEC>

0x308 - Disable interrupt

status: Reg<STATUS_SPEC>

0x400 - Status

enable: Reg<ENABLE_SPEC>

0x500 - Enable or disable ADC

ch: [CH; 8]

0x510..0x590 - Unspecified

resolution: Reg<RESOLUTION_SPEC>

0x5f0 - Resolution configuration

oversample: Reg<OVERSAMPLE_SPEC>

0x5f4 - Oversampling configuration. OVERSAMPLE should not be combined with SCAN. The RESOLUTION is applied before averaging, thus for high OVERSAMPLE a higher RESOLUTION should be used.

samplerate: Reg<SAMPLERATE_SPEC>

0x5f8 - Controls normal or continuous sample rate

result: RESULT

0x62c..0x638 - RESULT EasyDMA channel

Auto Trait Implementations

Blanket Implementations

Gets the TypeId of self. Read more

Immutably borrows from an owned value. Read more

Mutably borrows from an owned value. Read more

Performs the conversion.

Performs the conversion.

The type returned in the event of a conversion error.

Performs the conversion.

The type returned in the event of a conversion error.

Performs the conversion.