Struct lpc845_pac::adc0::dat::OVERRUN_R [−][src]
pub struct OVERRUN_R(_);
Expand description
Field OVERRUN
reader - This bit will be set to a 1 if a new conversion on this channel completes and overwrites the previous contents of the RESULT field before it has been read - i.e. while the DONE bit is set. This bit is cleared, along with the DONE bit, whenever this register is read or when the data related to this channel is read from either of the global SEQn_GDAT registers. This bit (in any of the 12 registers) will cause an overrun interrupt/DMA trigger to be asserted if the overrun interrupt is enabled. While it is allowed to include the same channels in both conversion sequences, doing so may cause erratic behavior of the DONE and OVERRUN bits in the data registers associated with any of the channels that are shared between the two sequences. Any erratic OVERRUN behavior will also affect overrun interrupt generation, if enabled.
Methods from Deref<Target = FieldReader<bool, bool>>
Returns true
if the bit is clear (0).
Returns true
if the bit is set (1).