pub fn write_fmt(args: Arguments<'_>) -> usizeExpand description
Synchronously writes one formatted emergency record.
The call itself does not queue work, allocate, or sleep. Once the emergency path claims a runtime UART, normal worker and IRQ register access remains excluded until shutdown so fatal records cannot be interleaved.