pub fn declared_point_endpoints(
occurrence: &str,
part_document: &Value,
) -> Vec<WireHarnessEndpoint>Expand description
A placed component’s connection points, namespaced — the shape
resolve_component_pin reads when a caller has the part’s declarations
rather than a routing report (an eCAD refresh before the new parts have run).
occurrence is the chain the points are placed under, so a device nested a
level down passes ACOMP7:ACOMP1 and its points address as
ACOMP7:ACOMP1:J1.VCC. WireHarnessEndpoint::component is the OUTERMOST
occurrence, which is what the scene lane’s owning_component reports for
the same address.