Expand description
Configuration register
Structs
Enums
Early wakeup interrupt When set, an interrupt occurs whenever the counter reaches the value 0x40. This interrupt is only cleared by hardware after a reset.
Timer base The timebase of the prescaler can be modified as follows:
Type Definitions
Field EWI
reader - Early wakeup interrupt When set, an interrupt occurs whenever the counter reaches the value 0x40. This interrupt is only cleared by hardware after a reset.
Field EWI
writer - Early wakeup interrupt When set, an interrupt occurs whenever the counter reaches the value 0x40. This interrupt is only cleared by hardware after a reset.
Field WDGTB
reader - Timer base The timebase of the prescaler can be modified as follows:
Field WDGTB
writer - Timer base The timebase of the prescaler can be modified as follows:
Field W
reader - 7-bit window value These bits contain the window value to be compared with the down-counter.
Field W
writer - 7-bit window value These bits contain the window value to be compared with the down-counter.