Expand description
FDCAN interrupt register
Structs
Type Definitions
Field ARA
reader - Access to reserved address
Field ARA
writer - Access to reserved address
Field BO
reader - Bus_Off status
Field BO
writer - Bus_Off status
Field ELO
reader - Error logging overflow
Field ELO
writer - Error logging overflow
Field EP
reader - Error passive
Field EP
writer - Error passive
Field EW
reader - Warning status
Field EW
writer - Warning status
Field HPM
reader - High-priority message
Field HPM
writer - High-priority message
Field MRAF
reader - Message RAM access failure The flag is set when the Rx handler: has not completed acceptance filtering or storage of an accepted message until the arbitration field of the following message has been received. In this case acceptance filtering or message storage is aborted and the Rx Handler starts processing of the following message. was unable to write a message to the message RAM. In this case message storage is aborted. In both cases the FIFO put index is not updated. The partly stored message is overwritten when the next message is stored to this location. The flag is also set when the Tx Handler was not able to read a message from the Message RAM in time. In this case message transmission is aborted. In case of a Tx Handler access failure the FDCAN is switched into Restricted Operation Mode (see mode). To leave Restricted Operation Mode, the Host CPU has to reset CCCR.ASM.
Field MRAF
writer - Message RAM access failure The flag is set when the Rx handler: has not completed acceptance filtering or storage of an accepted message until the arbitration field of the following message has been received. In this case acceptance filtering or message storage is aborted and the Rx Handler starts processing of the following message. was unable to write a message to the message RAM. In this case message storage is aborted. In both cases the FIFO put index is not updated. The partly stored message is overwritten when the next message is stored to this location. The flag is also set when the Tx Handler was not able to read a message from the Message RAM in time. In this case message transmission is aborted. In case of a Tx Handler access failure the FDCAN is switched into Restricted Operation Mode (see mode). To leave Restricted Operation Mode, the Host CPU has to reset CCCR.ASM.
Field PEA
reader - Protocol error in arbitration phase (nominal bit time is used)
Field PEA
writer - Protocol error in arbitration phase (nominal bit time is used)
Field PED
reader - Protocol error in data phase (data bit time is used)
Field PED
writer - Protocol error in data phase (data bit time is used)
Field RF0F
reader - Rx FIFO 0 full
Field RF0F
writer - Rx FIFO 0 full
Field RF0L
reader - Rx FIFO 0 message lost
Field RF0L
writer - Rx FIFO 0 message lost
Field RF0N
reader - Rx FIFO 0 new message
Field RF0N
writer - Rx FIFO 0 new message
Field RF1F
reader - Rx FIFO 1 full
Field RF1F
writer - Rx FIFO 1 full
Field RF1L
reader - Rx FIFO 1 message lost
Field RF1L
writer - Rx FIFO 1 message lost
Field RF1N
reader - Rx FIFO 1 new message
Field RF1N
writer - Rx FIFO 1 new message
Field TCF
reader - Transmission cancellation finished
Field TCF
writer - Transmission cancellation finished
Field TC
reader - Transmission completed
Field TC
writer - Transmission completed
Field TEFF
reader - Tx event FIFO full
Field TEFF
writer - Tx event FIFO full
Field TEFL
reader - Tx event FIFO element lost
Field TEFL
writer - Tx event FIFO element lost
Field TEFN
reader - Tx event FIFO New Entry
Field TEFN
writer - Tx event FIFO New Entry
Field TFE
reader - Tx FIFO empty
Field TFE
writer - Tx FIFO empty
Field TOO
reader - Timeout occurred
Field TOO
writer - Timeout occurred
Field TSW
reader - Timestamp wraparound
Field TSW
writer - Timestamp wraparound
Field WDI
reader - Watchdog interrupt
Field WDI
writer - Watchdog interrupt