Expand description

control register 1

Structs

control register 1

Register CR1 reader

Register CR1 writer

Enums

Auto-reload preload enable

Counter enable Note: External clock and gated mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

Clock division This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (tDTS)used by the dead-time generators and the digital filters (TIx),

One pulse mode

Update disable This bit is set and cleared by software to enable/disable UEV event generation. Counter overflow/underflow Setting the UG bit Update generation through the slave mode controller Buffered registers are then loaded with their preload values.

Update request source This bit is set and cleared by software to select the UEV event sources. Counter overflow/underflow Setting the UG bit Update generation through the slave mode controller

Type Definitions

Field ARPE reader - Auto-reload preload enable

Field ARPE writer - Auto-reload preload enable

Field CEN reader - Counter enable Note: External clock and gated mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

Field CEN writer - Counter enable Note: External clock and gated mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

Field CKD reader - Clock division This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (tDTS)used by the dead-time generators and the digital filters (TIx),

Field CKD writer - Clock division This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (tDTS)used by the dead-time generators and the digital filters (TIx),

Field OPM reader - One pulse mode

Field OPM writer - One pulse mode

Field UDIS reader - Update disable This bit is set and cleared by software to enable/disable UEV event generation. Counter overflow/underflow Setting the UG bit Update generation through the slave mode controller Buffered registers are then loaded with their preload values.

Field UDIS writer - Update disable This bit is set and cleared by software to enable/disable UEV event generation. Counter overflow/underflow Setting the UG bit Update generation through the slave mode controller Buffered registers are then loaded with their preload values.

Field UIFREMAP reader - UIF status bit remapping

Field UIFREMAP writer - UIF status bit remapping

Field URS reader - Update request source This bit is set and cleared by software to select the UEV event sources. Counter overflow/underflow Setting the UG bit Update generation through the slave mode controller

Field URS writer - Update request source This bit is set and cleared by software to select the UEV event sources. Counter overflow/underflow Setting the UG bit Update generation through the slave mode controller