Expand description

control register

Structs

Field ADD1H reader - Add 1 hour (summer time change)

Field ADD1H writer - Add 1 hour (summer time change)

Field ALRAE reader - Alarm A enable

Field ALRAE writer - Alarm A enable

Field ALRAIE reader - Alarm A interrupt enable

Field ALRAIE writer - Alarm A interrupt enable

Field ALRBE reader - Alarm B enable

Field ALRBE writer - Alarm B enable

Field ALRBIE reader - Alarm B interrupt enable

Field ALRBIE writer - Alarm B interrupt enable

Field BKP reader - Backup

Field BKP writer - Backup

Field BYPSHAD reader - Bypass the shadow registers

Field BYPSHAD writer - Bypass the shadow registers

Field COE reader - Calibration output enable

Field COE writer - Calibration output enable

Field COSEL reader - Calibration output selection

Field COSEL writer - Calibration output selection

control register

Field DCE reader - Coarse digital calibration enable

Field DCE writer - Coarse digital calibration enable

Field FMT reader - Hour format

Field FMT writer - Hour format

Field OSEL reader - Output selection

Field OSEL writer - Output selection

Field POL reader - Output polarity

Field POL writer - Output polarity

Register CR reader

Field REFCKON reader - Reference clock detection enable (50 or 60 Hz)

Field REFCKON writer - Reference clock detection enable (50 or 60 Hz)

Field SUB1H reader - Subtract 1 hour (winter time change)

Field SUB1H writer - Subtract 1 hour (winter time change)

Field TSEDGE reader - Time-stamp event active edge

Field TSEDGE writer - Time-stamp event active edge

Field TSE reader - Time stamp enable

Field TSE writer - Time stamp enable

Field TSIE reader - Time-stamp interrupt enable

Field TSIE writer - Time-stamp interrupt enable

Register CR writer

Field WUCKSEL reader - Wakeup clock selection

Field WUCKSEL writer - Wakeup clock selection

Field WUTE reader - Wakeup timer enable

Field WUTE writer - Wakeup timer enable

Field WUTIE reader - Wakeup timer interrupt enable

Field WUTIE writer - Wakeup timer interrupt enable

Enums

Add 1 hour (summer time change)

Alarm A enable

Alarm A interrupt enable

Alarm B enable

Alarm B interrupt enable

Backup

Bypass the shadow registers

Calibration output enable

Calibration output selection

Hour format

Output selection

Output polarity

Reference clock detection enable (50 or 60 Hz)

Subtract 1 hour (winter time change)

Time-stamp event active edge

Time stamp enable

Time-stamp interrupt enable

Wakeup clock selection

Wakeup timer enable

Wakeup timer interrupt enable