Crate rmodbus[][src]

rmodbus - Modbus for Rust

A framework to build fast and reliable Modbus-powered applications.

Cargo crate: https://crates.io/crates/rmodbus

What is rmodbus

rmodbus is not a yet another Modbus client/server. rmodbus is a set of tools to quickly build Modbus-powered applications.

Why yet another Modbus lib?

  • rmodbus is transport and protocol independent

  • rmodbus is platform independent (no_std is fully supported!)

  • can be easily used in blocking and async (non-blocking) applications

  • tuned for speed and reliability

  • provides a set of tools to easily work with Modbus context

  • supports client/server frame processing for Modbus TCP/UDP, RTU and ASCII.

  • server context can be easily managed, imported and exported

So the server isn’t included?

Yes, there’s no server included. You build the server by your own. You choose protocol, technology and everything else. rmodbus just process frames and works with Modbus context.

Here’s an example of a simple TCP blocking server:

use std::io::{Read, Write};
use std::net::TcpListener;
use std::thread;
 
use lazy_static::lazy_static;
 
use std::sync::RwLock;
 
use rmodbus::{
    server::{context::ModbusContext, ModbusFrame},
    ModbusFrameBuf, ModbusProto,
};
 
lazy_static! {
    pub static ref CONTEXT: RwLock<ModbusContext> = RwLock::new(ModbusContext::new());
}
 
pub fn tcpserver(unit: u8, listen: &str) {
    let listener = TcpListener::bind(listen).unwrap();
    println!("listening started, ready to accept");
    for stream in listener.incoming() {
        thread::spawn(move || {
            println!("client connected");
            let mut stream = stream.unwrap();
            loop {
                let mut buf: ModbusFrameBuf = [0; 256];
                let mut response = Vec::new(); // for nostd use FixedVec with alloc [u8;256]
                if stream.read(&mut buf).unwrap_or(0) == 0 {
                    return;
                }
                let mut frame = ModbusFrame::new(unit, &buf, ModbusProto::TcpUdp, &mut response);
                if frame.parse().is_err() {
                    println!("server error");
                    return;
                }
                if frame.processing_required {
                    let result = match frame.readonly {
                        true => frame.process_read(&CONTEXT.read().unwrap()),
                        false => frame.process_write(&mut CONTEXT.write().unwrap()),
                    };
                    if result.is_err() {
                        println!("frame processing error");
                        return;
                    }
                }
                if frame.response_required {
                    frame.finalize_response().unwrap();
                    println!("{:x?}", response.as_slice());
                    if stream.write(response.as_slice()).is_err() {
                        return;
                    }
                }
            }
        });
    }
}

There are also examples for Serial-RTU, Serial-ASCII and UDP in examples folder (if you’re reading this text somewhere else, visit rmodbus project repository.

Running examples:

cargo run --example app --features std
cargo run --example tcpserver --features std

Modbus context

The rule is simple: one standard Modbus context per application. 10k+10k 16-bit registers and 10k+10k coils are usually more than enough. This takes about 43Kbytes of RAM, but if you need to reduce context size, download library source and change CONTEXT_SIZE constant in “context.rs”.

rmodbus server context is thread-safe, easy to use and has a lot of functions.

Every time Modbus context is accessed, a context mutex must be locked. This slows down a performance, but guarantees that the context always has valid data after bulk-sets or after 32-bit data types were written. So make sure your application locks context only when required and only for a short period time.

Take a look at simple PLC example:

use std::fs::File;
use std::io::{Write};
 
use rmodbus::server::context::ModbusContext;
 
fn looping() {
    println!("Loop started");
    loop {
        // READ WORK MODES ETC
        let ctx = srv::CONTEXT.read().unwrap();
        let _param1 = ctx.get_holding(1000).unwrap();
        let _param2 = ctx.get_holdings_as_f32(1100).unwrap(); // ieee754 f32
        let _param3 = ctx.get_holdings_as_u32(1200).unwrap(); // u32
        let cmd = ctx.get_holding(1500).unwrap();
        drop(ctx);
        if cmd != 0 {
            println!("got command code {}", cmd);
            let mut ctx = srv::CONTEXT.write().unwrap();
            ctx.set_holding(1500, 0).unwrap();
            match cmd {
                1 => {
                    println!("saving memory context");
                    let _ = save("/tmp/plc1.dat", &ctx).map_err(|_| {
                        eprintln!("unable to save context!");
                    });
                }
                _ => println!("command not implemented"),
            }
        }
        // ==============================================
        // DO SOME JOB
        // ..........
        // WRITE RESULTS
        let mut ctx = srv::CONTEXT.write().unwrap();
        ctx.set_coil(0, true).unwrap();
        ctx.set_holdings_bulk(10, &(vec![10, 20])).unwrap();
        ctx.set_inputs_from_f32(20, 935.77).unwrap();
    }
}
 
fn save(fname: &str, ctx: &ModbusContext) -> Result<(), std::io::Error> {
    let mut file = match File::create(fname) {
        Ok(v) => v,
        Err(e) => return Err(e),
    };
    for i in ctx.iter() {
        match file.write(&[i]) {
            Ok(_) => {}
            Err(e) => return Err(e),
        }
    }
    match file.sync_all() {
        Ok(_) => {}
        Err(e) => return Err(e),
    }
    return Ok(());
}

To let the above program communicate with outer world, Modbus server must be up and running in the separate thread, asynchronously or whatever is preferred.

no_std

rmodbus supports no_std mode. Most of the library code is written the way to support both std and no_std.

Set dependency as:

rmodbus = { version = "*", features = ["nostd"] }

Small context

Default Modbus context has 10000 registers of each type, which requires 42500 bytes total. For systems with small RAM amount it’s possible to reduce the context size to the 1000 registers of each type (4250 bytes) with the following feature:

rmodbus = { version = "*", features = ["nostd", "smallcontext"] }

Vectors

Some of rmodbus functions use vectors to store result. In std mode, either standard std::vec::Vec or FixedVec can be used. In nostd mode, only FixedVec is supported.

Modbus client

Modbus client is designed with same principles as the server: the crate gives frame generator / processor, while the frames can be read / written with any source and with any required way.

TCP client Example:

use std::io::{Read, Write};
use std::net::TcpStream;
use std::time::Duration;
 
use rmodbus::{client::ModbusRequest, guess_response_frame_len, ModbusProto};
 
fn main() {
    let timeout = Duration::from_secs(1);
 
    // open TCP connection
    let mut stream = TcpStream::connect("localhost:5502").unwrap();
    stream.set_read_timeout(Some(timeout)).unwrap();
    stream.set_write_timeout(Some(timeout)).unwrap();
 
    // create request object
    let mut mreq = ModbusRequest::new(1, ModbusProto::TcpUdp);
    mreq.tr_id = 2; // just for test, default tr_id is 1
 
    // set 2 coils
    let mut request = Vec::new();
    mreq.generate_set_coils_bulk(0, &[true, true], &mut request)
        .unwrap();
 
    // write request to stream
    stream.write(&request).unwrap();
 
    // read first 6 bytes of response frame
    let mut buf = [0u8; 6];
    stream.read_exact(&mut buf).unwrap();
    let mut response = Vec::new();
    response.extend_from_slice(&buf);
    let len = guess_response_frame_len(&buf, ModbusProto::TcpUdp).unwrap();
    // read rest of response frame
    if len > 6 {
        let mut rest = vec![0u8; (len - 6) as usize];
        stream.read_exact(&mut rest).unwrap();
        response.extend(rest);
    }
    // check if frame has no Modbus error inside
    mreq.parse_ok(&response).unwrap();
 
    // get coil values back
    mreq.generate_get_coils(0, 2, &mut request).unwrap();
    stream.write(&request).unwrap();
    let mut buf = [0u8; 6];
    stream.read_exact(&mut buf).unwrap();
    let mut response = Vec::new();
    response.extend_from_slice(&buf);
    let len = guess_response_frame_len(&buf, ModbusProto::TcpUdp).unwrap();
    if len > 6 {
        let mut rest = vec![0u8; (len - 6) as usize];
        stream.read_exact(&mut rest).unwrap();
        response.extend(rest);
    }
    let mut data = Vec::new();
    // check if frame has no Modbus error inside and parse response bools into data vec
    mreq.parse_bool(&response, &mut data).unwrap();
    for i in 0..data.len() {
        println!("{} {}", i, data[i]);
    }
}

Changelog

v0.5

  • Common functions and structures moved to main crate module

  • Modbus client

v0.4

  • Modbus context is no longer created automatically and no mutex guard is provided by default. Use ModbusContext::new() to create context object and then use it as you wish - protect with any kind of Mutex, with RwLock or just put into UnsafeCell.

  • Context SDK changes: all functions moved inside context, removed unnecessary ones, function args optimized.

  • FixedVec support included by default, both in std and nostd.

  • Added support for 64-bit integers

Modules

client
server

Enums

ErrorKind
ModbusProto

Modbus protocol selection for frame processing

Constants

MODBUS_ERROR_ILLEGAL_DATA_ADDRESS
MODBUS_ERROR_ILLEGAL_DATA_VALUE
MODBUS_ERROR_ILLEGAL_FUNCTION
MODBUS_GET_COILS
MODBUS_GET_DISCRETES
MODBUS_GET_HOLDINGS
MODBUS_GET_INPUTS
MODBUS_SET_COIL
MODBUS_SET_COILS_BULK
MODBUS_SET_HOLDING
MODBUS_SET_HOLDINGS_BULK

Traits

VectorTrait

Functions

generate_ascii_frame

Generate ASCII frame

guess_request_frame_len

Guess request frame length

guess_response_frame_len

Guess response frame length

parse_ascii_frame

Parse ASCII Modbus frame

Type Definitions

ModbusFrameBuf

Standard Modbus frame buffer