Module nrf52832_pac::nfct

source ·
Expand description

NFC-A compatible radio

Modules

Current value driven to the NFC Load Control
NFC Error Status register
Auto collision resolution process has started
NFC Auto collision resolution error reported.
RX buffer (as defined by PACKETPTR and MAXLEN) in Data RAM full.
Transmission of data in RAM has ended, and EasyDMA has ended accessing the TX buffer
NFC error reported. The ERRORSTATUS register contains details on the source of the error.
Remote NFC field detected
Remote NFC field lost
The NFC peripheral is ready to receive and send frames
NFC RX frame error reported. The FRAMESTATUS.RX register contains details on the source of the error.
Received data have been checked (CRC, parity) and transferred to RAM, and EasyDMA has ended accessing the RX buffer
Marks the end of the first symbol of a received frame
NFC Auto collision resolution successfully completed
EasyDMA is ready to receive or send frames.
Marks the end of the last transmitted on-air symbol of a frame
Marks the start of the first symbol of a transmitted frame
Indicates the presence or not of a valid field
Maximum frame delay
Minimum frame delay
Configuration register for the Frame Delay Timer
Register block Unspecified
Enable or disable interrupt
Disable interrupt
Enable interrupt
Size of allocated for TXD and RXD data storage buffer in Data RAM
Second last NFCID1 part (7 or 10 bytes ID)
Third last NFCID1 part (10 bytes ID)
Last NFCID1 part (4, 7 or 10 bytes ID)
Packet pointer for TXD and RXD data storage in Data RAM
Register block Unspecified
NFC-A SEL_RES auto-response settings
NFC-A SENS_RES auto-response settings
Shortcut register
Activate NFC peripheral for incoming and outgoing frames, change state to activated
Disable NFC peripheral
Initializes the EasyDMA for receive.
Force state machine to IDLE state
Force state machine to SLEEP_A state
Enable NFC sense field mode, change state to sense mode
Start transmission of a outgoing frame, change state to transmit
Register block Unspecified

Structs

Current value driven to the NFC Load Control
NFC Error Status register
Auto collision resolution process has started
NFC Auto collision resolution error reported.
RX buffer (as defined by PACKETPTR and MAXLEN) in Data RAM full.
Transmission of data in RAM has ended, and EasyDMA has ended accessing the TX buffer
NFC error reported. The ERRORSTATUS register contains details on the source of the error.
Remote NFC field detected
Remote NFC field lost
The NFC peripheral is ready to receive and send frames
NFC RX frame error reported. The FRAMESTATUS.RX register contains details on the source of the error.
Received data have been checked (CRC, parity) and transferred to RAM, and EasyDMA has ended accessing the RX buffer
Marks the end of the first symbol of a received frame
NFC Auto collision resolution successfully completed
EasyDMA is ready to receive or send frames.
Marks the end of the last transmitted on-air symbol of a frame
Marks the start of the first symbol of a transmitted frame
Indicates the presence or not of a valid field
Maximum frame delay
Minimum frame delay
Configuration register for the Frame Delay Timer
Register block
Enable or disable interrupt
Disable interrupt
Enable interrupt
Size of allocated for TXD and RXD data storage buffer in Data RAM
Second last NFCID1 part (7 or 10 bytes ID)
Third last NFCID1 part (10 bytes ID)
Last NFCID1 part (4, 7 or 10 bytes ID)
Packet pointer for TXD and RXD data storage in Data RAM
Register block
Register block
NFC-A SEL_RES auto-response settings
NFC-A SENS_RES auto-response settings
Shortcut register
Activate NFC peripheral for incoming and outgoing frames, change state to activated
Disable NFC peripheral
Initializes the EasyDMA for receive.
Force state machine to IDLE state
Force state machine to SLEEP_A state
Enable NFC sense field mode, change state to sense mode
Start transmission of a outgoing frame, change state to transmit
Register block