Module lpc845_pac::sct0::ctrl[][src]

Expand description

SCT control register

Structs

Field BIDIR_H reader - Direction select

Field BIDIR_H writer - Direction select

Field BIDIR_L reader - L or unified counter direction select

Field BIDIR_L writer - L or unified counter direction select

Field CLRCTR_H reader - Writing a 1 to this bit clears the H counter. This bit always reads as 0.

Field CLRCTR_H writer - Writing a 1 to this bit clears the H counter. This bit always reads as 0.

Field CLRCTR_L reader - Writing a 1 to this bit clears the L or unified counter. This bit always reads as 0.

Field CLRCTR_L writer - Writing a 1 to this bit clears the L or unified counter. This bit always reads as 0.

SCT control register

Field DOWN_H reader - This bit is 1 when the H counter is counting down. Hardware sets this bit when the counter is counting, a counter limit condition occurs, and BIDIR is 1. Hardware clears this bit when the counter is counting down and a limit condition occurs or when the counter reaches 0.

Field DOWN_H writer - This bit is 1 when the H counter is counting down. Hardware sets this bit when the counter is counting, a counter limit condition occurs, and BIDIR is 1. Hardware clears this bit when the counter is counting down and a limit condition occurs or when the counter reaches 0.

Field DOWN_L reader - This bit is 1 when the L or unified counter is counting down. Hardware sets this bit when the counter is counting up, counter limit occurs, and BIDIR = 1.Hardware clears this bit when the counter is counting down and a limit condition occurs or when the counter reaches 0.

Field DOWN_L writer - This bit is 1 when the L or unified counter is counting down. Hardware sets this bit when the counter is counting up, counter limit occurs, and BIDIR = 1.Hardware clears this bit when the counter is counting down and a limit condition occurs or when the counter reaches 0.

Field HALT_H reader - When this bit is 1, the H counter does not run and no events can occur. A reset sets this bit. When the HALT_H bit is one, the STOP_H bit is cleared. It is possible to remove the halt condition while keeping the SCT in the stop condition (not running) with a single write to this register to simultaneously clear the HALT bit and set the STOP bit. Once set, this bit can only be cleared by software to restore counter operation. This bit is set on reset.

Field HALT_H writer - When this bit is 1, the H counter does not run and no events can occur. A reset sets this bit. When the HALT_H bit is one, the STOP_H bit is cleared. It is possible to remove the halt condition while keeping the SCT in the stop condition (not running) with a single write to this register to simultaneously clear the HALT bit and set the STOP bit. Once set, this bit can only be cleared by software to restore counter operation. This bit is set on reset.

Field HALT_L reader - When this bit is 1, the L or unified counter does not run and no events can occur. A reset sets this bit. When the HALT_L bit is one, the STOP_L bit is cleared. It is possible to remove the halt condition while keeping the SCT in the stop condition (not running) with a single write to this register to simultaneously clear the HALT bit and set the STOP bit. Once set, only software can clear this bit to restore counter operation. This bit is set on reset.

Field HALT_L writer - When this bit is 1, the L or unified counter does not run and no events can occur. A reset sets this bit. When the HALT_L bit is one, the STOP_L bit is cleared. It is possible to remove the halt condition while keeping the SCT in the stop condition (not running) with a single write to this register to simultaneously clear the HALT bit and set the STOP bit. Once set, only software can clear this bit to restore counter operation. This bit is set on reset.

Field PRE_H reader - Specifies the factor by which the SCT clock is prescaled to produce the H counter clock. The counter clock is clocked at the rate of the SCT clock divided by PRELH+1. Clear the counter (by writing a 1 to the CLRCTR bit) whenever changing the PRE value.

Field PRE_H writer - Specifies the factor by which the SCT clock is prescaled to produce the H counter clock. The counter clock is clocked at the rate of the SCT clock divided by PRELH+1. Clear the counter (by writing a 1 to the CLRCTR bit) whenever changing the PRE value.

Field PRE_L reader - Specifies the factor by which the SCT clock is prescaled to produce the L or unified counter clock. The counter clock is clocked at the rate of the SCT clock divided by PRE_L+1. Clear the counter (by writing a 1 to the CLRCTR bit) whenever changing the PRE value.

Field PRE_L writer - Specifies the factor by which the SCT clock is prescaled to produce the L or unified counter clock. The counter clock is clocked at the rate of the SCT clock divided by PRE_L+1. Clear the counter (by writing a 1 to the CLRCTR bit) whenever changing the PRE value.

Register CTRL reader

Field STOP_H reader - When this bit is 1 and HALT is 0, the H counter does not, run but I/O events related to the counter can occur. If such an event matches the mask in the Start register, this bit is cleared and counting resumes.

Field STOP_H writer - When this bit is 1 and HALT is 0, the H counter does not, run but I/O events related to the counter can occur. If such an event matches the mask in the Start register, this bit is cleared and counting resumes.

Field STOP_L reader - When this bit is 1 and HALT is 0, the L or unified counter does not run, but I/O events related to the counter can occur. If a designated start event occurs, this bit is cleared and counting resumes.

Field STOP_L writer - When this bit is 1 and HALT is 0, the L or unified counter does not run, but I/O events related to the counter can occur. If a designated start event occurs, this bit is cleared and counting resumes.

Register CTRL writer

Enums

Direction select

L or unified counter direction select