Module lpc845_pac::ctimer0::ccr [−][src]
Expand description
Capture Control Register. The CCR controls which edges of the capture inputs are used to load the Capture Registers and whether or not an interrupt is generated when a capture takes place.
Structs
Field CAP0FE
reader - Falling edge of capture channel 0: a sequence of 1 then 0 causes CR0 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP0FE
writer - Falling edge of capture channel 0: a sequence of 1 then 0 causes CR0 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP0I
reader - Generate interrupt on channel 0 capture event: a CR0 load generates an interrupt.
Field CAP0I
writer - Generate interrupt on channel 0 capture event: a CR0 load generates an interrupt.
Field CAP0RE
reader - Rising edge of capture channel 0: a sequence of 0 then 1 causes CR0 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP0RE
writer - Rising edge of capture channel 0: a sequence of 0 then 1 causes CR0 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP1FE
reader - Falling edge of capture channel 1: a sequence of 1 then 0 causes CR1 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP1FE
writer - Falling edge of capture channel 1: a sequence of 1 then 0 causes CR1 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP1I
reader - Generate interrupt on channel 1 capture event: a CR1 load generates an interrupt.
Field CAP1I
writer - Generate interrupt on channel 1 capture event: a CR1 load generates an interrupt.
Field CAP1RE
reader - Rising edge of capture channel 1: a sequence of 0 then 1 causes CR1 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP1RE
writer - Rising edge of capture channel 1: a sequence of 0 then 1 causes CR1 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP2FE
reader - Falling edge of capture channel 2: a sequence of 1 then 0 causes CR2 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP2FE
writer - Falling edge of capture channel 2: a sequence of 1 then 0 causes CR2 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP2I
reader - Generate interrupt on channel 2 capture event: a CR2 load generates an interrupt.
Field CAP2I
writer - Generate interrupt on channel 2 capture event: a CR2 load generates an interrupt.
Field CAP2RE
reader - Rising edge of capture channel 2: a sequence of 0 then 1 causes CR2 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP2RE
writer - Rising edge of capture channel 2: a sequence of 0 then 1 causes CR2 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP3FE
reader - Falling edge of capture channel 3: a sequence of 1 then 0 causes CR3 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP3FE
writer - Falling edge of capture channel 3: a sequence of 1 then 0 causes CR3 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP3I
reader - Generate interrupt on channel 3 capture event: a CR3 load generates an interrupt.
Field CAP3I
writer - Generate interrupt on channel 3 capture event: a CR3 load generates an interrupt.
Field CAP3RE
reader - Rising edge of capture channel 3: a sequence of 0 then 1 causes CR3 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Field CAP3RE
writer - Rising edge of capture channel 3: a sequence of 0 then 1 causes CR3 to be loaded with the contents of TC. 0 = disabled. 1 = enabled.
Capture Control Register. The CCR controls which edges of the capture inputs are used to load the Capture Registers and whether or not an interrupt is generated when a capture takes place.
Register CCR
reader
Register CCR
writer