Type Definition lpc81x_pac::lpc810::spi0::dly::PRE_DELAY_W

source ·
pub type PRE_DELAY_W<'a, const O: u8> = FieldWriter<'a, u32, DLY_SPEC, u8, u8, 4, O>;
Expand description

Field PRE_DELAY writer - Controls the amount of time between SSEL assertion and the beginning of a data transfer. There is always one SPI clock time between SSEL assertion and the first clock edge. This is not considered part of the pre-delay. 0x0 = No additional time is inserted. 0x1 = 1 SPI clock time is inserted. 0x2 = 2 SPI clock times are inserted. 0xF = 15 SPI clock times are inserted.