ACTIVATE_R | Field ACTIVATE reader - 0: disabled 1: activated Update rythm for VAL depends on COUNTER_CFG if data_sel is set to COUNTER.
|
ACTIVATE_W | Field ACTIVATE writer - 0: disabled 1: activated Update rythm for VAL depends on COUNTER_CFG if data_sel is set to COUNTER.
|
DATA_SEL_R | Field DATA_SEL reader - Selects source on which to apply online test: 00: LSB of COUNTER: raw data from one or all sources of entropy 01: MSB of COUNTER: raw data from one or all sources of entropy 10: RANDOM_NUMBER 11: ENCRYPTED_NUMBER ‘activate’ should be set to ‘disabled’ before changing this field.
|
DATA_SEL_W | Field DATA_SEL writer - Selects source on which to apply online test: 00: LSB of COUNTER: raw data from one or all sources of entropy 01: MSB of COUNTER: raw data from one or all sources of entropy 10: RANDOM_NUMBER 11: ENCRYPTED_NUMBER ‘activate’ should be set to ‘disabled’ before changing this field.
|
ONLINE_TEST_CFG_SPEC | no description available
|
R | Register ONLINE_TEST_CFG reader
|
W | Register ONLINE_TEST_CFG writer
|