Module lpc177x_8x::pwm0 [−][src]
Pulse Width Modulators (PWM0/1)
Modules
ccr |
Capture Control Register. The CCR controls which edges of the capture inputs are used to load the Capture Registers and whether or not an interrupt is generated for a capture event. |
cr |
PWM Control Register. Enables PWM outputs and selects either single edge or double edge controlled PWM outputs. |
ctcr |
Count Control Register. The CTCR selects between Timer and Counter mode, and in Counter mode selects the signal and edge(s) for counting. |
ir |
Interrupt Register. The IR can be written to clear interrupts, or read to identify which PWM interrupt sources are pending. |
ler |
Load Enable Register. Enables use of updated PWM match values. |
mcr |
Match Control Register. The MCR is used to control whether an interrupt is generated and if the PWM counter is reset when a Match occurs. |
mra |
Match Register. Match registers are continuously compared to the PWM counter in order to control PWM output edges. |
mrb |
Match Register. Match registers are continuously compared to the PWM counter in order to control PWM output edges. |
pc |
Prescale Counter. Prescaler for the main PWM counter. |
pcr |
PWM Control Register. Enables PWM outputs and selects either single edge or double edge controlled PWM outputs. |
pr |
Prescale Register. Determines how often the PWM counter is incremented. |
tc |
Timer Counter. The 32 bit TC is incremented every PR+1 cycles of PCLK. The TC is controlled through the TCR. |
tcr |
Timer Control Register. The TCR is used to control the Timer Counter functions. |
Structs
CCR |
Capture Control Register. The CCR controls which edges of the capture inputs are used to load the Capture Registers and whether or not an interrupt is generated for a capture event. |
CR |
PWM Control Register. Enables PWM outputs and selects either single edge or double edge controlled PWM outputs. |
CTCR |
Count Control Register. The CTCR selects between Timer and Counter mode, and in Counter mode selects the signal and edge(s) for counting. |
IR |
Interrupt Register. The IR can be written to clear interrupts, or read to identify which PWM interrupt sources are pending. |
LER |
Load Enable Register. Enables use of updated PWM match values. |
MCR |
Match Control Register. The MCR is used to control whether an interrupt is generated and if the PWM counter is reset when a Match occurs. |
MRA |
Match Register. Match registers are continuously compared to the PWM counter in order to control PWM output edges. |
MRB |
Match Register. Match registers are continuously compared to the PWM counter in order to control PWM output edges. |
PC |
Prescale Counter. Prescaler for the main PWM counter. |
PCR |
PWM Control Register. Enables PWM outputs and selects either single edge or double edge controlled PWM outputs. |
PR |
Prescale Register. Determines how often the PWM counter is incremented. |
RegisterBlock |
Register block |
TC |
Timer Counter. The 32 bit TC is incremented every PR+1 cycles of PCLK. The TC is controlled through the TCR. |
TCR |