1
   2
   3
   4
   5
   6
   7
   8
   9
  10
  11
  12
  13
  14
  15
  16
  17
  18
  19
  20
  21
  22
  23
  24
  25
  26
  27
  28
  29
  30
  31
  32
  33
  34
  35
  36
  37
  38
  39
  40
  41
  42
  43
  44
  45
  46
  47
  48
  49
  50
  51
  52
  53
  54
  55
  56
  57
  58
  59
  60
  61
  62
  63
  64
  65
  66
  67
  68
  69
  70
  71
  72
  73
  74
  75
  76
  77
  78
  79
  80
  81
  82
  83
  84
  85
  86
  87
  88
  89
  90
  91
  92
  93
  94
  95
  96
  97
  98
  99
 100
 101
 102
 103
 104
 105
 106
 107
 108
 109
 110
 111
 112
 113
 114
 115
 116
 117
 118
 119
 120
 121
 122
 123
 124
 125
 126
 127
 128
 129
 130
 131
 132
 133
 134
 135
 136
 137
 138
 139
 140
 141
 142
 143
 144
 145
 146
 147
 148
 149
 150
 151
 152
 153
 154
 155
 156
 157
 158
 159
 160
 161
 162
 163
 164
 165
 166
 167
 168
 169
 170
 171
 172
 173
 174
 175
 176
 177
 178
 179
 180
 181
 182
 183
 184
 185
 186
 187
 188
 189
 190
 191
 192
 193
 194
 195
 196
 197
 198
 199
 200
 201
 202
 203
 204
 205
 206
 207
 208
 209
 210
 211
 212
 213
 214
 215
 216
 217
 218
 219
 220
 221
 222
 223
 224
 225
 226
 227
 228
 229
 230
 231
 232
 233
 234
 235
 236
 237
 238
 239
 240
 241
 242
 243
 244
 245
 246
 247
 248
 249
 250
 251
 252
 253
 254
 255
 256
 257
 258
 259
 260
 261
 262
 263
 264
 265
 266
 267
 268
 269
 270
 271
 272
 273
 274
 275
 276
 277
 278
 279
 280
 281
 282
 283
 284
 285
 286
 287
 288
 289
 290
 291
 292
 293
 294
 295
 296
 297
 298
 299
 300
 301
 302
 303
 304
 305
 306
 307
 308
 309
 310
 311
 312
 313
 314
 315
 316
 317
 318
 319
 320
 321
 322
 323
 324
 325
 326
 327
 328
 329
 330
 331
 332
 333
 334
 335
 336
 337
 338
 339
 340
 341
 342
 343
 344
 345
 346
 347
 348
 349
 350
 351
 352
 353
 354
 355
 356
 357
 358
 359
 360
 361
 362
 363
 364
 365
 366
 367
 368
 369
 370
 371
 372
 373
 374
 375
 376
 377
 378
 379
 380
 381
 382
 383
 384
 385
 386
 387
 388
 389
 390
 391
 392
 393
 394
 395
 396
 397
 398
 399
 400
 401
 402
 403
 404
 405
 406
 407
 408
 409
 410
 411
 412
 413
 414
 415
 416
 417
 418
 419
 420
 421
 422
 423
 424
 425
 426
 427
 428
 429
 430
 431
 432
 433
 434
 435
 436
 437
 438
 439
 440
 441
 442
 443
 444
 445
 446
 447
 448
 449
 450
 451
 452
 453
 454
 455
 456
 457
 458
 459
 460
 461
 462
 463
 464
 465
 466
 467
 468
 469
 470
 471
 472
 473
 474
 475
 476
 477
 478
 479
 480
 481
 482
 483
 484
 485
 486
 487
 488
 489
 490
 491
 492
 493
 494
 495
 496
 497
 498
 499
 500
 501
 502
 503
 504
 505
 506
 507
 508
 509
 510
 511
 512
 513
 514
 515
 516
 517
 518
 519
 520
 521
 522
 523
 524
 525
 526
 527
 528
 529
 530
 531
 532
 533
 534
 535
 536
 537
 538
 539
 540
 541
 542
 543
 544
 545
 546
 547
 548
 549
 550
 551
 552
 553
 554
 555
 556
 557
 558
 559
 560
 561
 562
 563
 564
 565
 566
 567
 568
 569
 570
 571
 572
 573
 574
 575
 576
 577
 578
 579
 580
 581
 582
 583
 584
 585
 586
 587
 588
 589
 590
 591
 592
 593
 594
 595
 596
 597
 598
 599
 600
 601
 602
 603
 604
 605
 606
 607
 608
 609
 610
 611
 612
 613
 614
 615
 616
 617
 618
 619
 620
 621
 622
 623
 624
 625
 626
 627
 628
 629
 630
 631
 632
 633
 634
 635
 636
 637
 638
 639
 640
 641
 642
 643
 644
 645
 646
 647
 648
 649
 650
 651
 652
 653
 654
 655
 656
 657
 658
 659
 660
 661
 662
 663
 664
 665
 666
 667
 668
 669
 670
 671
 672
 673
 674
 675
 676
 677
 678
 679
 680
 681
 682
 683
 684
 685
 686
 687
 688
 689
 690
 691
 692
 693
 694
 695
 696
 697
 698
 699
 700
 701
 702
 703
 704
 705
 706
 707
 708
 709
 710
 711
 712
 713
 714
 715
 716
 717
 718
 719
 720
 721
 722
 723
 724
 725
 726
 727
 728
 729
 730
 731
 732
 733
 734
 735
 736
 737
 738
 739
 740
 741
 742
 743
 744
 745
 746
 747
 748
 749
 750
 751
 752
 753
 754
 755
 756
 757
 758
 759
 760
 761
 762
 763
 764
 765
 766
 767
 768
 769
 770
 771
 772
 773
 774
 775
 776
 777
 778
 779
 780
 781
 782
 783
 784
 785
 786
 787
 788
 789
 790
 791
 792
 793
 794
 795
 796
 797
 798
 799
 800
 801
 802
 803
 804
 805
 806
 807
 808
 809
 810
 811
 812
 813
 814
 815
 816
 817
 818
 819
 820
 821
 822
 823
 824
 825
 826
 827
 828
 829
 830
 831
 832
 833
 834
 835
 836
 837
 838
 839
 840
 841
 842
 843
 844
 845
 846
 847
 848
 849
 850
 851
 852
 853
 854
 855
 856
 857
 858
 859
 860
 861
 862
 863
 864
 865
 866
 867
 868
 869
 870
 871
 872
 873
 874
 875
 876
 877
 878
 879
 880
 881
 882
 883
 884
 885
 886
 887
 888
 889
 890
 891
 892
 893
 894
 895
 896
 897
 898
 899
 900
 901
 902
 903
 904
 905
 906
 907
 908
 909
 910
 911
 912
 913
 914
 915
 916
 917
 918
 919
 920
 921
 922
 923
 924
 925
 926
 927
 928
 929
 930
 931
 932
 933
 934
 935
 936
 937
 938
 939
 940
 941
 942
 943
 944
 945
 946
 947
 948
 949
 950
 951
 952
 953
 954
 955
 956
 957
 958
 959
 960
 961
 962
 963
 964
 965
 966
 967
 968
 969
 970
 971
 972
 973
 974
 975
 976
 977
 978
 979
 980
 981
 982
 983
 984
 985
 986
 987
 988
 989
 990
 991
 992
 993
 994
 995
 996
 997
 998
 999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
use a2lmacros::a2l_specification;

use crate::a2ml;
use crate::writer;
use crate::tokenizer::A2lTokenType;
use crate::parser::{ParseContext, ParseError, ParserState};
use crate::ifdata;


/// Describes the location and formatting of an a2l block within a file
#[derive(PartialEq, Clone)]
pub struct BlockInfo<T> {
    pub incfile: Option<String>,
    pub line: u32,
    pub uid: u32,
    pub start_offset: u32,
    pub end_offset: u32,
    pub item_location: T
}


/// The trait A2lObject is implemented for all a2l objects as well as all objects generated by the a2ml_specification! macro.
/// It gives access to layout and location data which is tracked for each object in an a2l file.
pub trait A2lObject<T> {
    /// get a reference to the BlockInfo that describes the layout of the a2l object
    fn get_layout(&self) -> &BlockInfo<T>;

    /// get a mutable reference to the BlockInfo that describes the layout of the a2l object
    fn get_layout_mut(&mut self) -> &mut BlockInfo<T>;

    /// reset the location information on the a2l object. It will be treated like a new object when writing a file
    fn reset_location(&mut self);

    /// reset the reference to an include file on this objct and its children.
    /// This causes the object to be written into the output file instead of referenced through /include "filename"
    fn merge_includes(&mut self);

    /// get the source line number from which the current a2l object was loaded.
    /// Returns 0 if the object was newly created and not loaded from a file
    fn get_line(&self) -> u32;
}


/// The trait A2lObjectName is automatically implemented for named a2l objects
pub trait A2lObjectName {
    /// get the name of an a2l object.
    /// this trait is only implemented for those objects that have names, which is a subset of all objects
    fn get_name(&self) -> &str;
}


a2l_specification! {
    /// Contains all the objects of an A2lfile
    ///
    /// An instance of this struct is returned when an a2l file is loaded successfully
    keyword A2L_FILE {
        [-> ASAP2_VERSION]
        [-> A2ML_VERSION]   
        [-> PROJECT]!
    }

    /// Description of the addressing of table values or axis point values.
    ///
    /// Specification: predefined data types
    enum AddrType {
        PBYTE,
        PWORD,
        PLONG,
        PLONGLONG   (1.70 ..),
        DIRECT
    }

    /// Description of the word lengths in the ECU program.
    ///
    /// Specification: predefined data types (datasize)
    enum DataTypeSize {
        BYTE,
        WORD,
        LONG
    }

    /// Description of the basic data types in the ECU program.
    ///
    /// Specification: predefined data types
    enum DataType {
        UBYTE,
        SBYTE,
        UWORD,
        SWORD,
        ULONG,
        SLONG,
        A_UINT64       (1.60 ..),
        A_INT64        (1.60 ..),
        FLOAT16_IEEE   (1.71 ..),
        FLOAT32_IEEE,
        FLOAT64_IEEE
    }

    /// Description of the axis point sequence in the memory.
    ///
    /// Specification: predefined data types
    enum IndexOrder {
        INDEX_INCR,
        INDEX_DECR
    }

    /// Contains AML code for description of interface specific description data.
    ///
    /// Specification: 3.5.2
    block A2ML {
        // the A2ML block gets special treatment in the code generator based on the block name
    }

    /// A2ML_VERSION is currently ignored
    ///
    /// Specification: 3.5.3
    keyword A2ML_VERSION {
        uint version_no
        uint upgrade_no
    }

    /// Address of the EPROM identifier
    ///
    /// Specification: 3.5.4
    keyword ADDR_EPK {
        ulong address
    }

    /// Defines the alignment of byte-sized values in complex objects (maps and axis)
    ///
    /// Specification: 3.5.5
    keyword ALIGNMENT_BYTE {
        uint alignment_border
    }

    /// Defines the alignment of 32bit floats in complex objects (maps and axis)
    ///
    /// Specification: 3.5.6
    keyword ALIGNMENT_FLOAT32_IEEE {
        uint alignment_border
    }

    /// Defines the alignment of 64bit floats in complex objects (maps and axis)
    ///
    /// Specification: 3.5.7
    keyword ALIGNMENT_FLOAT64_IEEE {
        uint alignment_border
    }

    /// Defines the alignment of int64 values in complex objects (maps and axis)
    ///
    /// Specification: 3.5.8
    keyword ALIGNMENT_INT64 {
        uint alignment_border
    }

    /// Defines the alignment of long-sized values in complex objects (maps and axis)
    ///
    /// Specification: 3.5.9
    keyword ALIGNMENT_LONG {
        uint alignment_border
    }

    /// Defines the alignment of word-sized values in complex objects (maps and axis)
    ///
    /// Specification: 3.5.10
    keyword ALIGNMENT_WORD {
        uint alignment_border
    }

    /// An extended description text
    ///
    /// One ANNOTATION may represent a voluminous description. Its purpose is to be e.g.
    /// an application note which explains the function of an identifier for the calibration
    /// engineer.
    ///
    /// Specification: 3.5.11
    block ANNOTATION {
        [-> ANNOTATION_LABEL]
        [-> ANNOTATION_ORIGIN]
        [-> ANNOTATION_TEXT]
    }

    /// The title of an annotation
    ///
    /// Specification: 3.5.12
    keyword ANNOTATION_LABEL {
        string label
    }

    /// Identify who or which system has created an annotation
    ///
    /// Specification: 3.5.13
    keyword ANNOTATION_ORIGIN {
        string origin
    }

    /// Text of an annotation
    ///
    /// One ANNOTATION_TEXT may represent a multi-line description text
    ///
    /// Specification: 3.5.14
    block ANNOTATION_TEXT {
        {string annotation_text}* annotation_text_list
    }

    /// marks a measurement object as an array of <Number> measurement values
    ///
    /// Specification: 3.5.15
    keyword ARRAY_SIZE {
        uint number
    }

    /// Version of the ASAM MCD-2MC standard used by this file
    ///
    /// This keyword is mandatory. Example:
    ///     ASAP2_VERSION 1 61
    ///
    /// Specification: 3.5.16
    keyword ASAP2_VERSION {
        uint version_no
        uint upgrade_no
    }

    /// Description of the axis points
    ///
    /// Specification: 3.5.17
    enum AxisDescrAttribute {
        CURVE_AXIS,
        COM_AXIS,
        FIX_AXIS,
        RES_AXIS,
        STD_AXIS
    }

    /// Axis description within an adjustable object
    ///
    /// Specification: 3.5.17
    block AXIS_DESCR {
        AxisDescrAttribute attribute
        ident input_quantity
        ident conversion
        uint max_axis_points
        float lower_limit
        float upper_limit
        [-> ANNOTATION]*
        [-> AXIS_PTS_REF]
        [-> BYTE_ORDER]
        [-> CURVE_AXIS_REF]
        [-> DEPOSIT]
        [-> EXTENDED_LIMITS]
        [-> FIX_AXIS_PAR]
        [-> FIX_AXIS_PAR_DIST]
        [-> FIX_AXIS_PAR_LIST]
        [-> FORMAT]
        [-> MAX_GRAD]
        [-> MONOTONY]
        [-> PHYS_UNIT]    (1.60 ..)
        [-> READ_ONLY]
        [-> STEP_SIZE]    (1.60 ..)
    }

    /// Parameters for the handling of an axis points distribution
    ///
    /// Specification: 3.5.18
    block AXIS_PTS {
        ident name
        string long_identifier
        ulong address
        ident input_quantity
        ident deposit_record
        float max_diff
        ident conversion
        uint max_axis_points
        float lower_limit
        float upper_limit
        [-> ANNOTATION]*
        [-> BYTE_ORDER]
        [-> CALIBRATION_ACCESS]
        [-> DEPOSIT]
        [-> DISPLAY_IDENTIFIER]
        [-> ECU_ADDRESS_EXTENSION]
        [-> EXTENDED_LIMITS]
        [-> FORMAT]
        [-> FUNCTION_LIST]
        [-> GUARD_RAILS]
        [-> IF_DATA]*
        [-> MONOTONY]
        [-> PHYS_UNIT]     (1.60 ..)
        [-> READ_ONLY]
        [-> REF_MEMORY_SEGMENT]
        [-> STEP_SIZE]     (1.60 ..)
        [-> SYMBOL_LINK]
    }

    /// Reference to an AXIS_PTS record
    ///
    /// Specification: 3.5.19
    keyword AXIS_PTS_REF {
        ident axis_points
    }

    /// Description of the X, Y, Z, Z4 or Z5 axis points in memory
    ///
    /// Specification: 3.5.20
    keyword AXIS_PTS_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
        IndexOrder index_incr
        AddrType addressing
    }

    /// Description of rescaling the axis values of an adjustable object
    ///
    /// Specification: 3.5.21
    keyword AXIS_RESCALE_X /_Y /_Z / _4 / _5 {
        uint position
        DataType datatype
        uint max_number_of_rescale_pairs
        IndexOrder index_incr
        AddrType addressing
    }

    /// The BIT_MASK keyword can be used to mask out single bits of the value to be processed.
    ///
    /// Specification: 3.5.22
    keyword BIT_MASK {
        ulong mask
    }

    /// Used to perform bit operation on a value
    ///
    /// Specification: 3.5.23
    block BIT_OPERATION {
        [-> LEFT_SHIFT]
        [-> RIGHT_SHIFT]
        [-> SIGN_EXTEND]
    }

    /// Byte ordering of a value on the ECU
    ///
    /// Specification: 3.5.24
    enum ByteOrderEnum {
        LITTLE_ENDIAN        (.. 1.51),
        BIG_ENDIAN           (.. 1.51),
        MSB_LAST,
        MSB_FIRST,
        MSB_FIRST_MSW_LAST   (1.70 ..),
        MSB_LAST_MSW_FIRST   (1.70 ..)
    }

    /// Where the standard value does not apply this parameter can be used to specify the byte order
    ///
    /// Specification: 3.5.24
    keyword BYTE_ORDER {
        ByteOrderEnum byte_order
    }

    /// Type of access that is possible for a CHARACTERISTIC or AXIS_PTS object
    ///
    /// Specification: 3.5.25
    enum CalibrationAccessEnum {
        CALIBRATION,
        NO_CALIBRATION,
        NOT_IN_MCD_SYSTEM,
        OFFLINE_CALIBRATION
    }

    /// Specifies the access of a CHARACTERISTIC or AXIS_PTS for calibration
    ///
    /// Specification: 3.5.25
    keyword CALIBRATION_ACCESS {
        CalibrationAccessEnum calibration_access
    }

    /// calibration method specific data
    ///
    /// Specification: 3.5.26
    block CALIBRATION_HANDLE {
        {long handle}* handle_list
        [-> CALIBRATION_HANDLE_TEXT] (1.60 ..)
    }

    /// Additional text for a calibration handle
    ///
    /// Specification: 3.5.27
    keyword CALIBRATION_HANDLE_TEXT {
        string text
    }

    /// Indicates the different methods of access that are implemented in the ECU
    ///
    /// Valid strings are: "InCircuit", "SERAM", "DSERAP", "BSERAP"
    ///
    /// Specification: 3.5.28
    block CALIBRATION_METHOD {
        string method
        ulong version
        [-> CALIBRATION_HANDLE]
    }

    /// Specifies the type of an adjustable object
    ///
    /// Specification: 3.5.29
    enum CharacteristicType {
        ASCII,
        CURVE,
        MAP,
        CUBOID,
        CUBE_4  (1.60 ..),
        CUBE_5  (1.60 ..),
        VAL_BLK,
        VALUE
    }

    /// Specifies all the parameters of an adjustable object
    ///
    /// Specification: 3.5.29
    block CHARACTERISTIC {
        ident name
        string long_identifier
        CharacteristicType characteristic_type
        ulong address
        ident deposit
        float max_diff
        ident conversion
        float lower_limit
        float upper_limit
        [-> ANNOTATION]*
        [-> AXIS_DESCR]*
        [-> BIT_MASK]
        [-> BYTE_ORDER]
        [-> CALIBRATION_ACCESS]
        [-> COMPARISON_QUANTITY]
        [-> DEPENDENT_CHARACTERISTIC]
        [-> DISCRETE]   (1.60 ..)
        [-> DISPLAY_IDENTIFIER]
        [-> ECU_ADDRESS_EXTENSION]
        [-> ENCODING]   (1.70 ..)
        [-> EXTENDED_LIMITS]
        [-> FORMAT]
        [-> FUNCTION_LIST]
        [-> GUARD_RAILS]
        [-> IF_DATA]*
        [-> MAP_LIST]
        [-> MATRIX_DIM]
        [-> MAX_REFRESH]
        [-> MODEL_LINK]  (1.70 ..)
        [-> NUMBER]      // (.. 1.51) - causes too many deprecation warnings in real files
        [-> PHYS_UNIT]   (1.60 ..)
        [-> READ_ONLY]
        [-> REF_MEMORY_SEGMENT]
        [-> STEP_SIZE]   (1.60 ..)
        [-> SYMBOL_LINK] (1.60 ..)
        [-> VIRTUAL_CHARACTERISTIC]
    }

    /// Specifies the coefficients for the formula f(x) = (axx + bx + c) / (dxx + ex + f)
    ///
    /// Specification: 3.5.30
    keyword COEFFS {
        float a
        float b
        float c
        float d
        float e
        float f
    }

    /// Specifies the coefficients for the linear formula f(x) = ax + b
    ///
    /// Specification: 3.5.31
    keyword COEFFS_LINEAR {
        float a
        float b
    }

    /// references a valid MEASUREMENT
    ///
    /// Specification: 3.5.32
    keyword COMPARISON_QUANTITY {
        ident name
    }

    /// Describes how to convert internal input values to physical values
    ///
    /// Specification: 3.5.33
    enum ConversionType {
        IDENTICAL  (1.60 ..),
        FORM,
        LINEAR  (1.60 ..),
        RAT_FUNC,
        TAB_INTP,
        TAB_NOINTP,
        TAB_VERB
    }

    /// Specification of a conversion method from internal values to physical values
    ///
    /// Specification: 3.5.33
    block COMPU_METHOD {
        ident name
        string long_identifier
        ConversionType conversion_type
        string format
        string unit
        [-> COEFFS]
        [-> COEFFS_LINEAR]
        [-> COMPU_TAB_REF]
        [-> FORMULA]
        [-> REF_UNIT]
        [-> STATUS_STRING_REF]    (1.60 ..)
    }

    /// Conversion table for conversions that cannot be represented as a function
    ///
    /// Specification: 3.5.34
    block COMPU_TAB {
        ident name
        string long_identifier
        ConversionType conversion_type
        uint number_value_pairs
        {
            float in_val
            float out_val
        }* tab_entry
        [-> DEFAULT_VALUE]
        [-> DEFAULT_VALUE_NUMERIC]  (1.60 ..)
    }

    /// reference to a conversion table
    ///
    /// Specification: 3.5.35
    keyword COMPU_TAB_REF {
        ident conversion_table
    }

    /// Conversion table for the assignment of display strings to values. Typically used for enums.
    ///
    /// Specification: 3.5.36
    block COMPU_VTAB {
        ident name
        string long_identifier
        ConversionType conversion_type
        uint number_value_pairs
        {
            float in_val
            string out_val
        }* value_pairs
        [-> DEFAULT_VALUE]
    }

    /// Conversion table for the assignment of display strings to a value range
    ///
    /// Specification: 3.5.37
    block COMPU_VTAB_RANGE {
        ident name
        string long_identifier
        uint number_value_triples
        {
            float in_val_min
            float in_val_max
            string out_val
        }* value_triples
        [-> DEFAULT_VALUE]
    }

    /// Identifies the CPU used in the ECU
    ///
    /// Specification: 3.5.38
    keyword CPU_TYPE {
        string cpu
    }

    /// Used to specify the adjustable CURVE CHARACTERISTIC that is used to normalize or scale the axis in an AXIS_DESCR
    ///
    /// Specification: 3.5.39
    keyword CURVE_AXIS_REF {
        ident curve_axis
    }

    /// Allows a customer name to be specified
    ///
    /// Specification: 3.5.40
    keyword CUSTOMER {
        string customer
    }

    /// specify a customer number or identifier as a string
    ///
    /// Specification: 3.5.41
    keyword CUSTOMER_NO {
        string number
    }

    /// Data size in bits
    ///
    /// Specification: 3.5.42
    keyword DATA_SIZE {
        uint size
    }

    /// Defines which adjustable objects are used by a FUNCTION
    ///
    /// Specification: 3.5.43
    block DEF_CHARACTERISTIC {
        { ident identifier }* identifier_list
    }

    /// Sets the default text value of COMPU_TAB, COMPU_VTAB or COMPU_VTAB_RANGE
    ///
    /// Specification: 3.5.44
    keyword DEFAULT_VALUE {
        string display_string
    }

    /// Sets the default numerical value of COMPU_TAB, COMPU_VTAB or COMPU_VTAB_RANGE
    ///
    /// Specification: 3.5.45
    keyword DEFAULT_VALUE_NUMERIC {
        float display_value
    }

    /// Specify characteristics that depend on a formula
    ///
    /// Specification: 3.5.46
    block DEPENDENT_CHARACTERISTIC {
        string formula
        {ident characteristic}* characteristic_list
    }

    /// Deposit of the axis points of a characteristic curve or map
    ///
    /// Specification: 3.5.47
    enum DepositMode {
        ABSOLUTE,
        DIFFERENCE
    }

    /// Specifies how the axis points of a characteristic are deposited in memory
    ///
    /// Specification: 3.5.47
    keyword DEPOSIT {
        DepositMode mode
    }

    /// Indicates that a measurement or calibration object has discrete values which should not be interpolated
    ///
    /// Specification: 3.5.48
    keyword DISCRETE {}

    /// Gives the display name of a CHARACTERISTIC or MEASUREMENT value
    ///
    /// Specification: 3.5.49
    keyword DISPLAY_IDENTIFIER {
        ident display_name
    }

    /// Description of the distance operand in the deposit structure to compute the axis points for fixed characteristic curves and fixed characteristic maps
    ///
    /// Specification: 3.5.50
    keyword DIST_OP_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }

    /// String for identification of the control unit.
    ///
    /// Specification: 3.5.51
    keyword ECU {
        string control_unit
    }

    /// Provides the address of a MEASUREMENT
    ///
    /// Specification: 3.5.52
    keyword ECU_ADDRESS {
        ulong address
    }

    /// Used to specify additional address information
    ///
    /// Specification: 3.5.53
    keyword ECU_ADDRESS_EXTENSION {
        int extension
    }

    /// Provide an address offset in order to handle near pointers or variant coding
    ///
    /// Specification: 3.5.54
    keyword ECU_CALIBRATION_OFFSET {
        long offset
    }

    /// EPROM identifier
    ///
    /// Specification: 3.5.55
    keyword EPK {
        string identifier
    }

    /// Used to mask bits of a MEASUREMENT which indicate that the value is in error
    ///
    /// Specification: 3.5.56
    keyword ERROR_MASK {
        ulong mask
    }

    /// used to specify an extended range of values
    ///
    /// Specification: 3.5.57
    keyword EXTENDED_LIMITS {
        float lower_limit
        float upper_limit
    }

    /// Parameters for the calculation of fixed axis points: X_i = Offset + (i - 1)*2^shift 
    ///
    /// Specification: 3.5.58
    keyword FIX_AXIS_PAR {
        int offset
        int shift
        uint number_apo
    }

    /// Parameters for the calculation of fixed axis points: X_i = Offset + (i - 1)*distance 
    ///
    /// Specification: 3.5.59
    keyword FIX_AXIS_PAR_DIST {
        int offset
        int distance
        uint number_apo
    }

    /// A list of fixed axis point, as implemented on the ECU
    ///
    /// Specification: 3.5.60
    block FIX_AXIS_PAR_LIST {
        { float axis_pts_value }* axis_pts_value_list
    }

    /// Specifies the number of axis points available to CURVE, MAP, CUBOID, CUBE_4 or CUBE_5
    ///
    /// Specification: 3.5.61
    keyword FIX_NO_AXIS_PTS_X / _Y / _Z / _4 / _5 {
        uint number_of_axis_points
    }

    /// Describes how the 2-dimensional table values are mapped onto the 1-dimensional address space
    ///
    /// Specification: 3.5.62
    enum IndexMode {
        ALTERNATE_CURVES,
        ALTERNATE_WITH_X,
        ALTERNATE_WITH_Y,
        COLUMN_DIR,
        ROW_DIR
    }

    /// Description of the table values (function values) of an adjustable object
    ///
    /// Specification: 3.5.62
    keyword FNC_VALUES {
        uint position
        DataType datatype
        IndexMode index_mode
        AddrType address_type
    }

    /// Allows a display format string to be specified for a MEASUREMENT, CHARACTERISTIC or AXIS_PTS object
    ///
    /// Specification: 3.5.63
    keyword FORMAT {
        string format_string
    }

    /// Allows any kind of formula to be specified
    ///
    /// Specification: 3.5.64
    block FORMULA {
        string fx
        [-> FORMULA_INV]
    }

    /// Allows an inverse formula to be specified
    ///
    /// Specification: 3.5.65
    keyword FORMULA_INV {
        string gx
    }

    /// Defines a function frame to structure large amounts of measurement objects
    ///
    /// Specification: 3.5.66
    block FRAME {
        ident name
        string long_identifier
        uint scaling_unit
        ulong rate
        [-> FRAME_MEASUREMENT]
        [-> IF_DATA]*
    }

    /// Contains a list of identifiers of measurement objects
    ///
    /// Specification: 3.5.67
    keyword FRAME_MEASUREMENT {
        { ident identifier}* identifier_list
    }

    /// Describes the input, local, and output variables of a function on the ECU
    ///
    /// Specification: 3.5.68
    block FUNCTION {
        ident name
        string long_identifier
        [-> ANNOTATION]*
        [-> AR_COMPONENT]   (1.70 ..)
        [-> DEF_CHARACTERISTIC]
        [-> FUNCTION_VERSION]
        [-> IF_DATA]*    (1.60 ..)
        [-> IN_MEASUREMENT]
        [-> LOC_MEASUREMENT]
        [-> OUT_MEASUREMENT]
        [-> REF_CHARACTERISTIC]
        [-> SUB_FUNCTION]
    }

    /// a list of FUNCTION objects
    ///
    /// Specification: 3.5.69
    block FUNCTION_LIST {
        {ident name}* name_list
    }

    /// A string containing the version of a FUNCTION
    ///
    /// Specification: 3.5.70
    keyword FUNCTION_VERSION {
        string version_identifier
    }

    /// Defines a group of releated CHARACTERISTIC and MEASUREMENT objects
    ///
    /// Specification: 3.5.71
    block GROUP {
        ident name
        string long_identifier
        [-> ANNOTATION]*
        [-> FUNCTION_LIST]
        [-> IF_DATA]*     (1.60 ..)
        [-> REF_CHARACTERISTIC]
        [-> REF_MEASUREMENT]
        [-> ROOT]
        [-> SUB_GROUP]
    }

    /// Used to indicate that an adjustable CURVE, MAP or AXIS_PTS uses guard rails
    ///
    /// Specification: 3.5.72
    keyword GUARD_RAILS {}

    /// The header of a project
    ///
    /// Specification: 3.5.73
    block HEADER {
        string comment
        [-> PROJECT_NO]
        [-> VERSION]
    }

    /// used to describe that an 'identifier' is deposited in a specific position in the adjustable object
    ///
    /// Specification: 3.5.74
    keyword IDENTIFICATION {
        uint position
        DataType datatype
    }

    /// Interface specific data
    ///
    /// Specification: 3.5.75
    block IF_DATA {
        // the A2ML block gets special treatment in the code generator based on the block name
    }

    /// A list of measurement objects that are used as the inputs of a function
    ///
    /// Specification: 3.5.76
    block IN_MEASUREMENT {
        {ident identifier}* identifier_list
    }

    /// describes the layout of a multi-dimensional measurement array
    ///
    /// Specification: 3.5.77
    keyword LAYOUT {
        IndexMode index_mode
    }

    /// Used within BIT_OPERATION to left-shift the bits of a value
    ///
    /// Specification: 3.5.78
    keyword LEFT_SHIFT {
        ulong bitcount
    }

    /// A list of measurement objects that are local variables of a function
    ///
    /// Specification: 3.5.79
    block LOC_MEASUREMENT {
        {ident identifier}* identifier_list
    }

    /// used to specify the list of MAPs which comprise a CUBOID
    ///
    /// Specification: 3.5.80
    block MAP_LIST {
        {ident name}* name_list
    }

    /// describes the dimensions of a multidimensional array of values
    ///
    /// Specification: 3.5.81
    keyword MATRIX_DIM {
        {uint dim}* dim_list // note: changed for 1.70
    }

    /// specifies a maximum permissible gradient for an adjustable object
    ///
    /// Specification: 3.5.82
    keyword MAX_GRAD {
        float max_gradient
    }

    /// specifies the maximum refresh rate in the control unit
    ///
    /// Specification: 3.5.83
    keyword MAX_REFRESH {
        uint scaling_unit
        ulong rate
    }

    /// describes the parameters for a measurement object
    ///
    /// Specification: 3.5.84
    block MEASUREMENT {
        ident name
        string long_identifier
        DataType datatype
        ident conversion
        uint resolution
        float accuracy
        float lower_limit
        float upper_limit
        [-> ANNOTATION]*
        [-> ARRAY_SIZE] (.. 1.51)
        [-> BIT_MASK]
        [-> BIT_OPERATION]
        [-> BYTE_ORDER]
        [-> DISCRETE]  (1.60 ..)
        [-> DISPLAY_IDENTIFIER]
        [-> ECU_ADDRESS]
        [-> ECU_ADDRESS_EXTENSION]
        [-> ERROR_MASK]
        [-> FORMAT]
        [-> FUNCTION_LIST]
        [-> IF_DATA]*
        [-> LAYOUT]   (1.60 ..)
        [-> MATRIX_DIM]
        [-> MAX_REFRESH]
        [-> PHYS_UNIT]   (1.60 ..)
        [-> READ_WRITE]
        [-> REF_MEMORY_SEGMENT]
        [-> SYMBOL_LINK]   (1.60 ..)
        [-> VIRTUAL]
    }

    /// describes the types of program segments
    ///
    /// Specification: 3.5.85
    enum ProgType {
        PRG_CODE,
        PRG_DATA,
        PRG_RESERVED
    }

    /// describes the layout of the ECU memory
    ///
    /// Specification: 3.5.85
    block MEMORY_LAYOUT {
        ProgType prog_type
        ulong address
        ulong size
        long[5] offset
        [-> IF_DATA]*
    }

    /// Describes the types of data in the ECU program
    ///
    /// Specification: 3.5.86
    enum PrgType {
        CALIBRATION_VARIABLES,
        CODE,
        DATA,
        EXCLUDE_FROM_FLASH,
        OFFLINE_DATA,
        RESERVED,
        SERAM,
        VARIABLES
    }

    /// describes the type of memory used
    ///
    /// Specification: 3.5.86
    enum MemoryType {
        EEPROM,
        EPROM,
        FLASH,
        RAM,
        ROM,
        REGISTER,
        NOT_IN_ECU   (1.70 ..)
    }

    /// specifies if a given memory region is internal or external
    ///
    /// Specification: 3.5.86
    enum MemoryAttribute {
        INTERN,
        EXTERN
    }

    /// describes a memory segment of the ECU program
    ///
    /// Specification: 3.5.86
    block MEMORY_SEGMENT {
        ident name
        string long_identifier
        PrgType prg_type
        MemoryType memory_type
        MemoryAttribute attribute
        ulong address
        ulong size
        long[5] offset
        [-> IF_DATA]*
    }

    /// defines default values for the  entire module
    ///
    /// Specification: 3.5.87
    block MOD_COMMON {
        string comment
        [-> ALIGNMENT_BYTE]
        [-> ALIGNMENT_FLOAT16_IEEE]   (1.71 ..)
        [-> ALIGNMENT_FLOAT32_IEEE]
        [-> ALIGNMENT_FLOAT64_IEEE]
        [-> ALIGNMENT_INT64]    (1.60 ..)
        [-> ALIGNMENT_LONG]
        [-> ALIGNMENT_WORD]
        [-> BYTE_ORDER]
        [-> DATA_SIZE]
        [-> DEPOSIT]
        [-> S_REC_LAYOUT] (.. 1.60) // deprecated in 1.61: RECORD_LAYOUT is always mandatory
    }

    /// defines system information and management data for the module
    ///
    /// Specification: 3.5.88
    block MOD_PAR {
        string comment
        [-> ADDR_EPK]*
        [-> CALIBRATION_METHOD]*
        [-> CPU_TYPE]
        [-> CUSTOMER]
        [-> CUSTOMER_NO]
        [-> ECU]
        [-> ECU_CALIBRATION_OFFSET]
        [-> EPK]
        [-> MEMORY_LAYOUT]*
        [-> MEMORY_SEGMENT]*
        [-> NO_OF_INTERFACES]
        [-> PHONE_NO]
        [-> SUPPLIER]
        [-> SYSTEM_CONSTANT]*
        [-> USER]
        [-> VERSION]
    }

    /// The MODULE keyword describes a complete ECU or device with all adjustable and measurement objects, conversion methods and functions
    ///
    /// At least one module must be defined within the PROJECT
    ///
    /// Specification: 3.5.89
    block MODULE {
        ident name
        string long_identifier
        [-> A2ML]
        [-> AXIS_PTS]*
        [-> BLOB]*                     (1.70 ..)
        [-> CHARACTERISTIC]*
        [-> COMPU_METHOD]*
        [-> COMPU_TAB]*
        [-> COMPU_VTAB]*
        [-> COMPU_VTAB_RANGE]*
        [-> FRAME]*
        [-> FUNCTION]*
        [-> GROUP]*
        [-> IF_DATA]*
        [-> INSTANCE]*                 (1.70 ..)
        [-> MEASUREMENT]*
        [-> MOD_COMMON]
        [-> MOD_PAR]
        [-> RECORD_LAYOUT]*
        [-> TRANSFORMER]*              (1.70 ..)
        [-> TYPEDEF_BLOB]*             (1.70 ..)
        [-> TYPEDEF_AXIS]*             (1.70 ..)
        [-> TYPEDEF_CHARACTERISTIC]*   (1.70 ..)
        [-> TYPEDEF_MEASUREMENT]*      (1.70 ..)
        [-> TYPEDEF_STRUCTURE]*        (1.70 ..)
        [-> UNIT]*
        [-> USER_RIGHTS]*
        [-> VARIANT_CODING]
    }

    /// describes the possible ways an adjustment object can be monotonous
    ///
    /// Specification: 3.5.90
    enum MonotonyType {
        MON_DECREASE,
        MON_INCREASE,
        STRICT_DECREASE,
        STRICT_INCREASE,
        MONOTONOUS    (1.60 ..),
        STRICT_MON    (1.60 ..),
        NOT_MON       (1.60 ..)
    }


    /// specifies the monotony of an adjustment object
    ///
    /// Specification: 3.5.90
    keyword MONOTONY {
        MonotonyType monotony
    }

    /// Description of the number of axis points in an adjustable object
    ///
    /// Specification: 3.5.91
    keyword NO_AXIS_PTS_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }

    /// the number of interfaces
    ///
    /// Specification: 3.5.92
    keyword NO_OF_INTERFACES {
        uint num
    }

    /// number of rescaling axis point value pairs
    ///
    /// Specification: 3.5.93
    keyword NO_RESCALE_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }

    /// specifies the number of values in an array. Obsolete, replaced by MATRIX_DIM
    ///
    /// Specification: 3.5.94
    keyword NUMBER {
        uint number
    }

    /// Description of the 'offset' parameter in the deposit structure
    ///
    /// Specification: 3.5.95
    keyword OFFSET_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }

    /// defines output quantities of a function
    ///
    /// Specification: 3.5.96
    block OUT_MEASUREMENT {
        {ident identifier}* identifier_list
    }

    /// contains a phone number, e.g. of the calibration engineer
    ///
    /// Specification: 3.5.97
    keyword PHONE_NO {
        string telnum
    }

    /// specifies the physical unit of a measurement or calibration object as a string
    ///
    /// Specification: 3.5.98
    keyword PHYS_UNIT {
        string unit
    }

    /// Project description with project header and all modules belonging to the project. Required.
    ///
    /// Specification: 3.5.99
    block PROJECT {
        ident name
        string long_identifier
        [-> HEADER]
        [-> MODULE]+
    }

    /// Gives the project identifier
    ///
    /// Specification: 3.5.100
    keyword PROJECT_NO {
        ident project_number
    }

    /// used to indicate that an adjustable object is read-only
    ///
    /// Specification: 3.5.101
    keyword READ_ONLY {}

    /// used to indicate that a measurement object is writeable
    ///
    /// Specification: 3.5.102
    keyword READ_WRITE {}

    /// specifies the various data structures of an adjustable objects in memory
    ///
    /// Specification: 3.5.103
    block RECORD_LAYOUT {
        ident name
        [-> ALIGNMENT_BYTE]
        [-> ALIGNMENT_FLOAT16_IEEE]  (1.71 ..)
        [-> ALIGNMENT_FLOAT32_IEEE]
        [-> ALIGNMENT_FLOAT64_IEEE]
        [-> ALIGNMENT_INT64]
        [-> ALIGNMENT_LONG]
        [-> ALIGNMENT_WORD]
        [-> AXIS_PTS_X/_Y/_Z/_4/_5]
        [-> AXIS_RESCALE_X/_Y/_Z/_4/_5]
        [-> DIST_OP_X/_Y/_Z/_4/_5]
        [-> FIX_NO_AXIS_PTS_X/_Y/_Z/_4/_5]
        [-> FNC_VALUES]
        [-> IDENTIFICATION]
        [-> NO_AXIS_PTS_X/_Y/_Z/_4/_5]
        [-> NO_RESCALE_X/_Y/_Z/_4/_5]
        [-> OFFSET_X/_Y/_Z/_4/_5]
        [-> RESERVED]*
        [-> RIP_ADDR_W/_X/_Y/_Z/_4/_5]
        [-> SRC_ADDR_X/_Y/_Z/_4/_5]
        [-> SHIFT_OP_X/_Y/_Z/_4/_5]
        [-> STATIC_RECORD_LAYOUT]    (1.60 ..)
        [-> STATIC_ADDRESS_OFFSETS]  (1.70 ..)
    }

    /// defines a list of adjustable objects that can be referenced by a function or group
    ///
    /// Specification: 3.5.104
    block REF_CHARACTERISTIC {
        { ident identifier}* identifier_list
    }

    /// defines a list of groups for use by USER_RIGHTS
    ///
    /// Specification: 3.5.105
    block REF_GROUP {
        { ident identifier}* identifier_list
    }

    /// defines a list of measurement objects that can be referenced by a group
    ///
    /// Specification: 3.5.106
    block REF_MEASUREMENT {
        { ident identifier}* identifier_list
    }

    /// reference to a MEMORY_SEGMENT
    ///
    /// Specification: 3.5.107
    block REF_MEMORY_SEGMENT {
        ident name
    }

    /// reference to a UNIT
    ///
    /// Specification: 3.5.108
    block REF_UNIT {
        ident unit
    }

    /// indicates that the data at the given position is reserved and should not be interpreted by the MCD system
    ///
    /// Specification: 3.5.109
    keyword RESERVED {
        uint position
        DataTypeSize data_size
    }

    /// Used within BIT_OPERATION to right-shift the bits of a value
    ///
    /// Specification: 3.5.110
    keyword RIGHT_SHIFT {
        ulong bitcount
    }

    /// Describes the storage of the ECU-internal result of interpolation (RIP)
    ///
    /// Specification: 3.5.111
    keyword RIP_ADDR_W / _X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }
    
    /// indicates that the current group is at the root of the navigation tree
    ///
    /// Specification: 3.5.112
    keyword ROOT {}

    /// Description of the shift operand in the deposit structure to compute the axis points for fixed characteristic curves and fixed characteristic maps
    ///
    /// Specification: 3.5.113
    keyword SHIFT_OP_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }
    
    /// used in BIT_OPERATION to specify that sign extension should be performed
    ///
    /// Specification: 3.5.114
    keyword SIGN_EXTEND {}

    /// the seven base dimensions required to define an extended SI unit
    ///
    /// Specification: 3.5.115
    keyword SI_EXPONENTS {
        int length
        int mass
        int time
        int electric_current
        int temperature
        int amount_of_substance
        int luminous_intensity
    }

    /// Description of the address of the input quantity in an adjustable object
    ///
    /// Specification: 3.5.116
    keyword SRC_ADDR_X / _Y / _Z / _4 / _5 {
        uint position
        DataType datatype
    }

    /// indicates that an adjustable object with dynamic number of axis points does not compact or expand data when removing or inserting axis points
    ///
    /// Specification: 3.5.117
    keyword STATIC_RECORD_LAYOUT {}

    /// used to split up the value range of ECU internal values into a numerical and a verbal part
    ///
    /// Specification: 3.5.118
    keyword STATUS_STRING_REF {
        ident conversion_table
    }

    /// step size when adjusting the value of a CHARACTERISTIC, AXIS_PTS or AXIS_DESCR
    ///
    /// Specification: 3.5.119
    keyword STEP_SIZE {
        float step_size
    }

    /// a list of identifiers of functions which are sub-functions of the current function
    ///
    /// Specification: 3.5.120
    block SUB_FUNCTION {
        { ident identifier}* identifier_list
    }

    /// a list of identifiers of groups which are subgroups of the current group
    ///
    /// Specification: 3.5.121
    block SUB_GROUP {
        { ident identifier}* identifier_list
    }

    /// Name of the ECU manufacturer
    ///
    /// Specification: 3.5.122
    keyword SUPPLIER {
        string manufacturer
    }

    /// specifes the name of a symbol within a linker map file that corresponds to the a2l object
    ///
    /// Specification: 3.5.123
    keyword SYMBOL_LINK {
        string symbol_name
        long offset
    }

    /// defines a system constant that can be used in conversion formulas
    ///
    /// Specification: 3.5.124
    keyword SYSTEM_CONSTANT {
        string name
        string value
    }

    /// sets the standard record layout for the module
    ///
    /// Specification: 3.5.125
    keyword S_REC_LAYOUT {
        ident name
    }

    /// Type of the UNIT
    ///
    /// Specification: 3.5.126
    enum UnitType {
        DERIVED,
        EXTENDED_SI
    }

    /// Specification of a measurement unit
    ///
    /// Specification: 3.5.126
    block UNIT {
        ident name
        string long_identifier
        string display
        UnitType unit_type
        [-> REF_UNIT]
        [-> SI_EXPONENTS]
        [-> UNIT_CONVERSION]
    }

    /// Specification of the linear relationship between two measurement units
    ///
    /// Specification: 3.5.127
    keyword UNIT_CONVERSION {
        float gradient
        float offset
    }

    /// Name of the user
    ///
    /// Specification: 3.5.128
    keyword USER {
        string user_name
    }

    /// used to define groups accessible only for certain users
    ///
    /// Specification: 3.5.129
    block USER_RIGHTS {
        ident user_level_id
        [-> READ_ONLY]
        [-> REF_GROUP]*
    }

    /// define a list of start addresses of variant coded adjustable objects
    ///
    /// Specification: 3.5.130
    block VAR_ADDRESS {
        { ulong address}* address_list
    }

    /// defines one adjustable object to be variant coded
    ///
    /// Specification: 3.5.131
    block VAR_CHARACTERISTIC {
        ident name
        { ident criterion_name }* criterion_name_list
        [-> VAR_ADDRESS]
    }

    /// describes a variant criterion
    ///
    /// Specification: 3.5.132
    block VAR_CRITERION {
        ident name
        string long_identifier
        {ident  value}* value_list
        [-> VAR_MEASUREMENT]
        [-> VAR_SELECTION_CHARACTERISTIC]
    }

    /// describes a forbidden combination of values of different variant criteria
    ///
    /// Specification: 3.5.133
    block VAR_FORBIDDEN_COMB {
        {
            ident criterion_name
            ident criterion_value
        }* combination
    }

    /// specify a special measurement object which indicates the currently active variant
    ///
    /// Specification: 3.5.134
    keyword VAR_MEASUREMENT {
        ident name
    }

    /// intended to define the format of the variant extension. Currently only one format is supported
    ///
    /// Specification: 3.5.135
    enum VarNamingTag {
        NUMERIC
    }

    /// defines the format of the variant extension (index) of adjustable object names
    ///
    /// Specification: 3.5.135
    keyword VAR_NAMING {
        VarNamingTag tag
    }

    /// used to specify a special characteristic object which can change the currently active variant
    ///
    /// Specification: 3.5.136
    keyword VAR_SELECTION_CHARACTERISTIC {
        ident name
    }

    /// defines the separating symbol between the two parts of an adjustable object name
    ///
    /// Specification: 3.5.137
    keyword VAR_SEPARATOR {
        string separator
    }

    /// All information related to variant coding is grouped in this structure
    ///
    /// Specification: 3.5.138
    block VARIANT_CODING {
        [-> VAR_CHARACTERISTIC]*
        [-> VAR_CRITERION]*
        [-> VAR_FORBIDDEN_COMB]*
        [-> VAR_NAMING]
        [-> VAR_SEPARATOR]
    }

    /// version identifier
    ///
    /// Specification: 3.5.139
    keyword VERSION {
        string version_identifier
    }

    /// specification of the measurement objects for a virtual measurement channel
    ///
    /// Specification: 3.5.140
    block VIRTUAL {
        { ident measuring_channel }* measuring_channel_list
    }

    /// defines characteristics that are not deposited in the memory of the control unit, but can be used to indirectly calibrate other characteristic values
    ///
    /// Specification: 3.5.141
    block VIRTUAL_CHARACTERISTIC {
        string formula
        {ident characteristic }* characteristic_list
    }


    // ----------------------------------------------------------
    // new elements as of 1.7.0
    // ----------------------------------------------------------

    /// Describes the encoding of a string, if it is not ASCII
    enum CharacterEncoding {
        UTF8,
        UTF16,
        UTF32
    }

    /// Description of the addressing of table values or axis point values.
    keyword ADDRESS_TYPE {
        AddrType address_type
    }

    /// Defines the alignment of 16bit floats in complex objects (maps and axis)
    keyword ALIGNMENT_FLOAT16_IEEE {
        uint alignment_border
    }

    /// describes the Autosar component type of a function
    keyword AR_COMPONENT {
        string component_type
    }

    /// Special data object that can be used to handle domain specific data, which are processed inside the ECU in a dedicated way
    block BLOB {
        ident name
        string long_identifier
        ulong start_address
        ulong size
        [-> ADDRESS_TYPE]
        [-> ANNOTATION]*
        [-> CALIBRATION_ACCESS]
        [-> DISPLAY_IDENTIFIER]
        [-> ECU_ADDRESS_EXTENSION]
        [-> IF_DATA]*
        [-> MAX_REFRESH]
        [-> MODEL_LINK]
        [-> SYMBOL_LINK]
    }

    keyword CONSISTENT_EXCHANGE {}

    /// a CHARACTERISTIC of type ASCII can be configured to use a multi-byte encoding instead
    keyword ENCODING {
        CharacterEncoding encoding
    }

    /// Creates an instance of a type defined using TYPEDEF_STRUCTURE
    block INSTANCE {
        ident name
        string long_identifier
        ident type_ref
        ulong start_address
        [-> ADDRESS_TYPE]  (1.71 ..)
        [-> ANNOTATION]*
        [-> CALIBRATION_ACCESS]
        [-> DISPLAY_IDENTIFIER]
        [-> ECU_ADDRESS_EXTENSION]
        [-> IF_DATA]*
        [-> MATRIX_DIM]
        [-> MAX_REFRESH]
        [-> MODEL_LINK]
        [-> OVERWRITE]
        [-> READ_ONLY]
        [-> SYMBOL_LINK]
    }

    /// add a string to a CHARACTERISTIC linking it to a name in the model
    keyword MODEL_LINK {
        string model_link
    }

    /// override some default attributes of a type definition in a specific INSTANCE.
    /// Added in 1.70; currently incomplete and non-functional
    keyword OVERWRITE {
        // TODO
    }

    /// indicates that the start addresses of axes and function values of an adjustable object do not change when removing or inserting axis points
    keyword STATIC_ADDRESS_OFFSETS {}

    /// defines a single component of a TYPEDEF_STRUCTURE
    block STRUCTURE_COMPONENT {
        ident component_name
        ident component_type
        ulong size
        [-> ADDRESS_TYPE]  (1.71 ..)
        [-> LAYOUT]
        [-> MATRIX_DIM]
        [-> SYMBOL_TYPE_LINK]
    }

    /// Specifies the name of a symbol within a linker map file or debug file that describes a class, class member, structure or structure component
    keyword SYMBOL_TYPE_LINK {
        string symbol_type
    }

    /// the trigger conditions of a TRANSFORMER
    enum TransformerTrigger {
        ON_USER_REQUEST,
        ON_CHANGE
    }

    /// Definition of call to an external function (32-bit or 64-bit DLL) for converting calibration object values between their implementation format and physical format
    block TRANSFORMER {
        ident name
        string version
        string dllname_32bit
        string dllname_64bit
        uint timeout
        TransformerTrigger trigger
        ident inverse_transformer
        [-> TRANSFORMER_IN_OBJECTS]
        [-> TRANSFORMER_OUT_OBJECTS]
    }

    /// provides a list of inputs for a TRANSFORMER
    block TRANSFORMER_IN_OBJECTS {
        {ident identifier}* identifier_list
    }

    /// provides a list of outputs for a TRANSFORMER
    block TRANSFORMER_OUT_OBJECTS {
        {ident identifier}* identifier_list
    }

    /// Type definition of an axis object
    block TYPEDEF_AXIS {
        ident name
        string long_identifier
        ident input_quantity
        ident record_layout
        float max_diff
        ident conversion
        uint max_axis_points
        float lower_limit
        float upper_limit
        [-> BYTE_ORDER]
        [-> DEPOSIT]
        [-> EXTENDED_LIMITS]
        [-> FORMAT]
        [-> MONOTONY]
        [-> PHYS_UNIT]
        [-> STEP_SIZE]
    }

    /// Type definition of a BLOB
    block TYPEDEF_BLOB {
        ident name
        string long_identifier
        ulong size
        [-> ADDRESS_TYPE]  (1.71 ..)
    }

    /// Type definition of a calibration object
    block TYPEDEF_CHARACTERISTIC {
        ident name
        string long_identifier
        CharacteristicType characteristic_type
        ident record_layout
        float max_diff
        ident conversion
        float lower_limit
        float upper_limit
        [-> AXIS_DESCR]*
        [-> BIT_MASK]
        [-> BYTE_ORDER]
        [-> DISCRETE]
        [-> ENCODING]
        [-> EXTENDED_LIMITS]
        [-> FORMAT]
        [-> MATRIX_DIM]
        [-> NUMBER]     // (.. 1.51)
        [-> PHYS_UNIT]
        [-> STEP_SIZE]
    }

    /// Type definition of a measurement object
    block TYPEDEF_MEASUREMENT {
        ident name
        string long_identifier
        DataType datatype
        ident conversion
        uint resolution
        float accuracy
        float lower_limit
        float upper_limit
        [-> BIT_MASK]
        [-> BIT_OPERATION]
        [-> BYTE_ORDER]
        [-> ERROR_MASK]
        [-> DISCRETE]
        [-> FORMAT]
        [-> LAYOUT]
        [-> MATRIX_DIM]
        [-> PHYS_UNIT]
    }

    /// Definition of structured data types similar to the "typedef" command in C
    block TYPEDEF_STRUCTURE {
        ident name
        string long_identifier
        ulong total_size
        [-> ADDRESS_TYPE]
        [-> CONSISTENT_EXCHANGE]
        [-> STRUCTURE_COMPONENT]*
        [-> SYMBOL_TYPE_LINK]
    }
}


/// A2ML is a special case in the specification.
/// It contains the ASAP2 metalanguage code that describes the content of IF_DATA blocks
#[derive(Clone)]
pub struct A2ml {
    pub a2ml_text: String,
    pub(crate) __block_info: BlockInfo<(u32, ())>
}

impl std::fmt::Debug for A2ml {
    fn fmt(&self, f: &mut std::fmt::Formatter<'_>) -> std::fmt::Result {
        f.debug_struct("A2ml")
        .field("a2ml_text", &self.a2ml_text)
        .finish()
    }
}

impl A2ml {
    pub fn new(a2ml_text: String) -> Self {
        Self {
            a2ml_text,
            __block_info: BlockInfo {
                incfile: None,
                line: 0,
                uid: 0,
                start_offset: 1,
                end_offset: 1,
                item_location: (0, ())
            }
        }
    }

    pub(crate) fn parse(parser: &mut ParserState, context: &ParseContext, start_offset: u32) -> Result<Self, ParseError> {
        let fileid = parser.get_incfilename(context.fileid);
        let line = context.line;
        let uid = parser.get_next_id();

        let __a2ml_text_location = parser.get_current_line_offset();
        let token = parser.expect_token(context, A2lTokenType::String)?;
        let a2ml_text = parser.get_token_text(token).to_string();

        match a2ml::parse_a2ml(&a2ml_text) {
            Ok(a2mlspec) => parser.file_a2mlspec = Some(a2mlspec),
            Err(errmsg) => parser.error_or_log(ParseError::A2mlError(errmsg))?,
        }

        parser.expect_token(context, A2lTokenType::End)?;
        let ident = parser.get_identifier(context)?;
        if ident != "A2ML" {
            parser.error_or_log(ParseError::IncorrectEndTag(context.clone(), ident))?;
        }

        Ok(A2ml {
            a2ml_text,
            __block_info: BlockInfo {
                incfile: fileid,
                line,
                uid,
                start_offset,
                end_offset: 1, // the real offset is more difficult to calculate, because the a2ml text is the only multi-line element
                item_location: (__a2ml_text_location, ())
            }
        })
    }

    pub(crate) fn stringify(&self, indent: usize) -> String {
        let mut writer = writer::Writer::new(indent);
        writer.add_str(&self.a2ml_text, self.__block_info.item_location.0);
        writer.finish()
    }
}

impl A2lObject<(u32, ())> for A2ml {
    fn get_layout(&self) -> &BlockInfo<(u32, ())> {
        &self.__block_info
    }

    fn get_layout_mut(&mut self) -> &mut BlockInfo<(u32, ())> {
        &mut self.__block_info
    }

    // clear the location info (include filename and uid) of an object
    // unlike merge_includes() this function does not operate recursively
    fn reset_location(&mut self) {
        self.merge_includes();
        self.__block_info.uid = 0;
    }

    fn merge_includes(&mut self) {
        self.__block_info.incfile = None;
    }

    fn get_line(&self) -> u32 {
        self.__block_info.line
    }
}

// manual implementation of PartialEq that ignores __block_info: the layout/location doesn't matter when testing equality
impl PartialEq for A2ml {
    fn eq(&self, other: &Self) -> bool {
        self.a2ml_text == other.a2ml_text
    }
}


/// The content of IF_DATA blocks is not directly described in the specification.
/// Instead the content description is provided at runtime through the A2ML block.
#[derive(Clone)]
pub struct IfData {
    /// contains the content of the IF_DATA in generic form
    pub ifdata_items: Option<a2ml::GenericIfData>,
    /// ifdata_valid indicates if the data matched an A2ML specification during parsing or not
    pub ifdata_valid: bool,
    pub(crate) __block_info: BlockInfo<()>
}

impl std::fmt::Debug for IfData {
    fn fmt(&self, f: &mut std::fmt::Formatter<'_>) -> std::fmt::Result {
        f.debug_struct("IfData")
        .field("ifdata_items", &self.ifdata_items)
        .finish()
    }
}


impl IfData {
    pub fn new() -> Self {
        Self {
            ifdata_items: None,
            ifdata_valid: false,
            __block_info: BlockInfo {
                incfile: None,
                line: 0,
                uid: 0,
                start_offset: 1,
                end_offset: 1,
                item_location: ()
            }
        }
    }

    pub(crate) fn parse(parser: &mut ParserState, context: &ParseContext, start_offset: u32) -> Result<Self, ParseError> {
        let fileid = parser.get_incfilename(context.fileid);
        let line = context.line;
        let uid = parser.get_next_id();

        let (ifdata_items, ifdata_valid) = ifdata::parse_ifdata(parser, context)?;

        let end_offset = parser.get_current_line_offset();
        parser.expect_token(context, A2lTokenType::End)?;
        let ident = parser.get_identifier(context)?;
        if ident != "IF_DATA" {
            parser.error_or_log(ParseError::IncorrectEndTag(context.clone(), ident))?;
        }

        Ok(IfData {
            ifdata_items,
            ifdata_valid,
            __block_info: BlockInfo {
                incfile: fileid,
                line,
                uid,
                start_offset,
                end_offset,
                item_location: ()
            }
        })
    }

    pub(crate) fn stringify(&self, indent: usize) -> String {
        if let Some(ifdata_items) = &self.ifdata_items {
            // ifdata items were wrapped in an extra layer that would cause a double indent in the output
            ifdata_items.write(indent - 1)
        } else {
            "".to_string()
        }
    }
}

impl A2lObject<()> for IfData {
    fn get_layout(&self) -> &BlockInfo<()> {
        &self.__block_info
    }

    fn get_layout_mut(&mut self) -> &mut BlockInfo<()> {
        &mut self.__block_info
    }

    // clear the location info (include filename and uid) of an object
    // unlike merge_includes() this function does not operate recursively
    fn reset_location(&mut self) {
        self.merge_includes();
        self.__block_info.uid = 0;
    }

    fn merge_includes(&mut self) {
        self.__block_info.incfile = None;
        if let Some(ifdata_items) = &mut self.ifdata_items {
            // ifdata_items is an un-decoded GenericIfData. It can directly handle merge_includes()
            ifdata_items.merge_includes();
        }
    }

    fn get_line(&self) -> u32 {
        self.__block_info.line
    }
}

// manual implementation of PartialEq that ignores __block_info: the layout/location doesn't matter when testing equality
impl PartialEq for IfData {
    fn eq(&self, other: &Self) -> bool {
        self.ifdata_items == other.ifdata_items
    }
}