Module avrd::atmega406
[−]
[src]
The AVR ATmega406 microcontroller
Variants
Pinout | Mcuage | Operating temperature | Operating voltage | Max speed | |
---|---|---|---|---|---|
standard | 0°C - 0°C | 4V - 5.5V | 0 MHz |
Constants
ACS |
Bitfield on register CCSR |
BGCC |
Bitfield on register BGCCR |
BGCCR |
Bandgap Calibration Register. |
BGCRR |
Bandgap Calibration of Resistor Ladder. |
BGD |
Bitfield on register BGCCR |
BLB0 |
Bitfield on register LOCKBIT |
BLB1 |
Bitfield on register LOCKBIT |
BLBSET |
Bitfield on register SPMCSR |
BODRF |
Bitfield on register MCUSR |
BOOTRST |
Bitfield on register LOW |
BOOTSZ |
Bitfield on register LOW |
BPCR |
Battery Protection Control Register. |
BPDUV |
Battery Protection Deep Under Voltage Register. |
BPIR |
Battery Protection Interrupt Register. |
BPOCD |
Battery Protection OverCurrent Detection Level Register. |
BPPL |
Bitfield on register BPPLR |
BPPLE |
Bitfield on register BPPLR |
BPPLR |
Battery Protection Parameter Lock Register. |
BPSCD |
Battery Protection Short-Circuit Detection Level Register. |
C |
Bitfield on register SREG |
CADAC0 |
ADC Accumulate Current. |
CADAC1 |
ADC Accumulate Current. |
CADAC2 |
ADC Accumulate Current. |
CADAC3 |
ADC Accumulate Current. |
CADACIE |
Bitfield on register CADCSRB |
CADACIF |
Bitfield on register CADCSRB |
CADAS |
Bitfield on register CADCSRA |
CADCSRA |
CC-ADC Control and Status Register A. |
CADCSRB |
CC-ADC Control and Status Register B. |
CADEN |
Bitfield on register CADCSRA |
CADIC |
CC-ADC Instantaneous Current. |
CADICH |
CC-ADC Instantaneous Current high byte. |
CADICIE |
Bitfield on register CADCSRB |
CADICIF |
Bitfield on register CADCSRB |
CADICL |
CC-ADC Instantaneous Current low byte. |
CADRCC |
CC-ADC Regular Charge Current. |
CADRCIE |
Bitfield on register CADCSRB |
CADRCIF |
Bitfield on register CADCSRB |
CADRDC |
CC-ADC Regular Discharge Current. |
CADSE |
Bitfield on register CADCSRA |
CADSI |
Bitfield on register CADCSRA |
CADUB |
Bitfield on register CADCSRA |
CBCR |
Cell Balancing Control Register. |
CBE |
Bitfield on register CBCR |
CBPTR |
Current Battery Protection Timing Register. |
CCD |
Bitfield on register BPCR |
CCDL |
Bitfield on register BPOCD |
CCSR |
Clock Control and Status Register. |
CFE |
Bitfield on register FCSR |
COCIE |
Bitfield on register BPIR |
COCIF |
Bitfield on register BPIR |
COM0A |
Bitfield on register TCCR0A |
COM0B |
Bitfield on register TCCR0A |
CPS |
Bitfield on register FCSR |
CS0 |
Bitfield on register TCCR0B |
CS1 |
Bitfield on register TCCR1B |
CTC1 |
Bitfield on register TCCR1B |
DCD |
Bitfield on register BPCR |
DCDL |
Bitfield on register BPOCD |
DDRA |
Port A Data Direction Register. |
DDRB |
Port B Data Direction Register. |
DDRD |
Data Direction Register, Port D. |
DFE |
Bitfield on register FCSR |
DIDR0 |
Digital Input Disable Register. |
DOCIE |
Bitfield on register BPIR |
DOCIF |
Bitfield on register BPIR |
DUDL |
Bitfield on register BPDUV |
DUVD |
Bitfield on register BPCR |
DUVIE |
Bitfield on register BPIR |
DUVIF |
Bitfield on register BPIR |
DUVT |
Bitfield on register BPDUV |
EEAR |
EEPROM Address Register Bytes. |
EEARH |
EEPROM Address Register Bytes high byte. |
EEARL |
EEPROM Address Register Bytes low byte. |
EECR |
EEPROM Control Register. |
EEDR |
EEPROM Data Register. |
EEMPE |
Bitfield on register EECR |
EEPE |
Bitfield on register EECR |
EEPM |
Bitfield on register EECR |
EERE |
Bitfield on register EECR |
EERIE |
Bitfield on register EECR |
EESAVE |
Bitfield on register LOW |
EICRA |
External Interrupt Control Register. |
EIFR |
External Interrupt Flag Register. |
EIMSK |
External Interrupt Mask Register. |
EXTRF |
Bitfield on register MCUSR |
FCSR |
FCSR register |
FOC0A |
Bitfield on register TCCR0B |
FOC0B |
Bitfield on register TCCR0B |
FOSCCAL |
Fast Oscillator Calibration Value. |
GPIOR0 |
General Purpose IO Register 0. |
GPIOR1 |
General Purpose IO Register 1. |
GPIOR2 |
General Purpose IO Register 2. |
GTCCR |
General Timer/Counter Control Register. |
H |
Bitfield on register SREG |
HIGH |
HIGH register |
I |
Bitfield on register SREG |
INT |
Bitfield on register EIMSK |
INTF |
Bitfield on register EIFR |
ISC0 |
Bitfield on register EICRA |
ISC1 |
Bitfield on register EICRA |
ISC2 |
Bitfield on register EICRA |
ISC3 |
Bitfield on register EICRA |
IVCE |
Bitfield on register MCUCR |
IVSEL |
Bitfield on register MCUCR |
JTAGEN |
Bitfield on register HIGH |
JTD |
Bitfield on register MCUCR |
JTRF |
Bitfield on register MCUSR |
LB |
Bitfield on register LOCKBIT |
LOCKBIT |
LOCKBIT register |
LOW |
LOW register |
MCUCR |
MCU Control Register. |
MCUSR |
MCU Status Register. |
N |
Bitfield on register SREG |
OCDEN |
Bitfield on register HIGH |
OCF0A |
Bitfield on register TIFR0 |
OCF0B |
Bitfield on register TIFR0 |
OCF1A |
Bitfield on register TIFR1 |
OCIE0A |
Bitfield on register TIMSK0 |
OCIE0B |
Bitfield on register TIMSK0 |
OCIE1A |
Bitfield on register TIMSK1 |
OCPT |
Bitfield on register CBPTR |
OCR0A |
Output compare Register A. |
OCR0B |
Output compare Register B. |
OCR1AH |
Output Compare Register 1A High byte. |
OCR1AL |
Output Compare Register 1A Low byte. |
PCICR |
Pin Change Interrupt Control Register. |
PCIE |
Bitfield on register PCICR |
PCIF |
Bitfield on register PCIFR |
PCIFR |
Pin Change Interrupt Flag Register. |
PCMSK0 |
Pin Change Enable Mask Register 0. |
PCMSK1 |
Pin Change Enable Mask Register 1. |
PFD |
Bitfield on register FCSR |
PGERS |
Bitfield on register SPMCSR |
PGWRT |
Bitfield on register SPMCSR |
PINA |
Port A Input Pins. |
PINB |
Port B Input Pins. |
PIND |
Input Pins, Port D. |
PORF |
Bitfield on register MCUSR |
PORTA |
Port A Data Register. |
PORTB |
Port B Data Register. |
PORTC |
Port C Data Register. |
PORTD |
Data Register, Port D. |
PRR0 |
Power Reduction Register 0. |
PRTIM0 |
Bitfield on register PRR0 |
PRTIM1 |
Bitfield on register PRR0 |
PRTWI |
Bitfield on register PRR0 |
PRVADC |
Bitfield on register PRR0 |
PSRSYNC |
Bitfield on register GTCCR |
PUD |
Bitfield on register MCUCR |
PWMOC |
Bitfield on register FCSR |
PWMOPC |
Bitfield on register FCSR |
RWWSB |
Bitfield on register SPMCSR |
RWWSRE |
Bitfield on register SPMCSR |
S |
Bitfield on register SREG |
SCD |
Bitfield on register BPCR |
SCDL |
Bitfield on register BPSCD |
SCIE |
Bitfield on register BPIR |
SCIF |
Bitfield on register BPIR |
SCPT |
Bitfield on register CBPTR |
SE |
Bitfield on register SMCR |
SIGRD |
Bitfield on register SPMCSR |
SM |
Bitfield on register SMCR |
SMCR |
Sleep Mode Control Register. |
SP |
Stack Pointer. |
SPH |
Stack Pointer high byte. |
SPL |
Stack Pointer low byte. |
SPMCSR |
Store Program Memory Control Register. |
SPMEN |
Bitfield on register SPMCSR |
SPMIE |
Bitfield on register SPMCSR |
SREG |
Status Register. |
SUT_CKSEL |
Bitfield on register LOW |
T |
Bitfield on register SREG |
TCCR0A |
Timer/Counter0 Control Register. |
TCCR0B |
Timer/Counter0 Control Register. |
TCCR1B |
Timer/Counter1 Control Register B. |
TCNT0 |
Timer Counter 0. |
TCNT1 |
Timer Counter 1 Bytes. |
TCNT1H |
Timer Counter 1 Bytes high byte. |
TCNT1L |
Timer Counter 1 Bytes low byte. |
TIFR0 |
Timer/Counter Interrupt Flag register. |
TIFR1 |
Timer/Counter Interrupt Flag register. |
TIMSK0 |
Timer/Counter Interrupt Mask Register. |
TIMSK1 |
Timer/Counter Interrupt Mask Register. |
TOIE0 |
Bitfield on register TIMSK0 |
TOIE1 |
Bitfield on register TIMSK1 |
TOV0 |
Bitfield on register TIFR0 |
TOV1 |
Bitfield on register TIFR1 |
TSM |
Bitfield on register GTCCR |
TWA |
Bitfield on register TWAR |
TWAM |
Bitfield on register TWAMR |
TWAMR |
TWI (Slave) Address Mask Register. |
TWAR |
TWI (Slave) Address register. |
TWBCIE |
Bitfield on register TWBCSR |
TWBCIF |
Bitfield on register TWBCSR |
TWBCIP |
Bitfield on register TWBCSR |
TWBCSR |
TWI Bus Control and Status Register. |
TWBDT |
Bitfield on register TWBCSR |
TWBR |
TWI Bit Rate register. |
TWCR |
TWI Control Register. |
TWDR |
TWI Data register. |
TWEA |
Bitfield on register TWCR |
TWEN |
Bitfield on register TWCR |
TWGCE |
Bitfield on register TWAR |
TWIE |
Bitfield on register TWCR |
TWINT |
Bitfield on register TWCR |
TWPS |
Bitfield on register TWSR |
TWS |
Bitfield on register TWSR |
TWSR |
TWI Status Register. |
TWSTA |
Bitfield on register TWCR |
TWSTO |
Bitfield on register TWCR |
TWWC |
Bitfield on register TWCR |
V |
Bitfield on register SREG |
VADC |
VADC Data Register Bytes. |
VADCCIE |
Bitfield on register VADCSR |
VADCCIF |
Bitfield on register VADCSR |
VADCH |
VADC Data Register Bytes high byte. |
VADCL |
VADC Data Register Bytes low byte. |
VADCSR |
The VADC Control and Status register. |
VADEN |
Bitfield on register VADCSR |
VADMUX |
The VADC multiplexer Selection Register. |
VADSC |
Bitfield on register VADCSR |
WDCE |
Bitfield on register WDTCSR |
WDE |
Bitfield on register WDTCSR |
WDIE |
Bitfield on register WDTCSR |
WDIF |
Bitfield on register WDTCSR |
WDP |
Bitfield on register WDTCSR |
WDRF |
Bitfield on register MCUSR |
WDTCSR |
Watchdog Timer Control Register. |
WDTON |
Bitfield on register LOW |
WGM0 |
Bitfield on register TCCR0A |
WGM02 |
Bitfield on register TCCR0B |
WUTCF |
Bitfield on register WUTCSR |
WUTCSR |
Wake-up Timer Control Register. |
WUTE |
Bitfield on register WUTCSR |
WUTIE |
Bitfield on register WUTCSR |
WUTIF |
Bitfield on register WUTCSR |
WUTP |
Bitfield on register WUTCSR |
WUTR |
Bitfield on register WUTCSR |
XOE |
Bitfield on register CCSR |
Z |
Bitfield on register SREG |